Robust Predictive Control Scheme for Permanent-Magnet Synchronous Generators Based Modern Wind Turbines

نویسندگان

چکیده

In this article, a deadbeat predictive control (DB-PC) strategy for permanent-magnet synchronous generators (PMSGs)-based modern wind turbines is proposed. The main advantages of the DB-PC technique are its excellent dynamics and constant switching frequency. However, idea obtaining actuation voltage next sample from mathematical model generator. Therefore, highly sensitive to mismatches in parameters PMSG. order obviate problem, disturbance estimator (extended Kalman filter (EKF)) employed work enhance robustness proposed scheme by estimating total due parameter adding it calculation voltage. Furthermore, same EKF observe rotor speed position PMSG, i.e., mechanical sensors not required. Moreover, able reduce harmonic distortion stator currents implemented laboratory. experimental results proved superiority over traditional technique.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-linear control of variable-speed wind turbines with permanent magnet synchronous generators: a robust backstepping approach

Robust adaptive control of nonlinear systems with unknown state delay A robust dynamic inversion technique for asymptotic tracking control of an aircraft Non-linear control of variable-speed wind turbines with permanent magnet synchronous generators: a robust backstepping approach A new robust nonlinear control algorithm for the regulation of blood glucose in diabetic patients Robust backsteppi...

متن کامل

Fault-Ride through Strategy for Permanent-Magnet Synchronous Generators in Variable-Speed Wind Turbines

Abstract: Currently, the electric power production by wind energy conversion systems (WECSs) has increased significantly. Consequently, wind turbine (WT) generators are requested to fulfill the grid code (GC) requirements stated by network operators. In case of grid faults/voltage dips, a mismatch between the generated active power from the wind generator and the active power delivered to the g...

متن کامل

An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions

Abstract: In recent years, the increasing penetration level of wind energy into power systems has brought new issues and challenges. One of the main concerns is the issue of dynamic response capability during outer disturbance conditions, especially the fault-tolerance capability during asymmetrical faults. In order to improve the fault-tolerance and dynamic response capability under asymmetric...

متن کامل

Wind Turbines with Permanent Magnet Synchronous Generator and Full-Power Converters: Modelling, Control and Simulation

Research about dynamic models for grid-connected wind energy conversion systems is one of the challenges to achieve knowledge for the ongoing change due to the intensification of using wind energy in nowadays. This book chapter is an involvement on those models, but dealing with wind energy conversion systems consisting of wind turbines with permanent magnet synchronous generators (PMSG) and fu...

متن کامل

Flicker Mitigation by Speed Control of Permanent Magnet Synchronous Generator Variable-Speed Wind Turbines

Grid-connected wind turbines are fluctuating power sources that may produce flicker during continuous operation. This paper presents a simulation model of a MW-level variable speed wind turbine with a full-scale back-to-back power converter and permanent magnet synchronous generator (PMSG) developed in the simulation tool of PSCAD/EMTDC. Flicker emission of this system is investigated. The 3p (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Electronics

سال: 2021

ISSN: ['2079-9292']

DOI: https://doi.org/10.3390/electronics10131596