Rod-cone interaction in flicker perimetry.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rod-cone interaction in flicker perimetry.

We have assessed the influence of the rod system on cone flicker sensitivity during flicker perimetry. For temporal frequencies above 18 Hz extrafoveal cone-mediated flicker thresholds for a white test stimulus are as much as 1.5 log units lower when measured against a large background light that saturates the rods than when measured in darkness. Following a Ganzfeld bleach extrafoveal cone fli...

متن کامل

Lateral suppression of mesopic rod and cone flicker detection.

This study investigated the mechanisms of flicker detection suppression by measuring mesopic rod and cone critical flicker frequencies (CFFs) at different center and surround illuminance levels. Stimuli were generated with a four-primary photostimulator that provided independent control of rod and cone excitations. The results showed that dim surrounds ≤0.2 Td suppressed cone-mediated CFFs at ≥...

متن کامل

Flicker VEPs reflecting multiple rod and cone pathways

In an attempt to determine whether the relative contributions of magno-mediated and parvo-mediated inputs to the cortex are significantly altered in the transition from cone to rod vision, VEPs were recorded at different luminance levels (photopic to scotopic) for 2Hz square-wave, isochromatic flicker. The VEP mass response appears capable of reflecting major parvo-mediated contributions even a...

متن کامل

Flicker perimetry resists retinal image degradation.

The influence of refractive defocus and artificial media opacities on perimetric thresholds in automated light-sense and flicker perimetry was investigated in 20 eyes of 20 normal subjects. Thresholds were determined at 13 locations in the central visual field up to 25 degrees. Refractive defocus was induced by blurring with glasses of +1, +2, +3, +6 and +9 diopters spherical. Three diffusers w...

متن کامل

Electroretinographic assessment of rod- and cone-mediated bipolar cell pathways using flicker stimuli in mice

Mouse full-field electroretinograms (ERGs) are dominated by responses of photoreceptors and depolarizing (ON-) bipolar cells, but not much of hyperpolarizing (OFF-) bipolar cells under conventional recording conditions. Here we investigate a novel ERG protocol in mice for functional assessment of the major ON- and OFF-bipolar cell pathways using flicker stimuli for a high luminance with varying...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Ophthalmology

سال: 1984

ISSN: 0007-1161

DOI: 10.1136/bjo.68.5.303