Rostock Cornea Module 2.0 - a versatile extension for anterior segment imaging
نویسندگان
چکیده
منابع مشابه
Contribution to comprehension of image formation in confocal microscopy of cornea with Rostock cornea module.
AIM To investigate the influence of refractive index of aqueous humour on imaging of corneal endothelium in confocal microscopy. To clarify the phenomenon of dark endothelial and bright epithelial cell membranes in confocal images of corneas. METHODS Use of a novel digital confocal laser scanning microscope, a combination of the Heidelberg retina tomograph (HRT II) and the Rostock cornea modu...
متن کاملEXTENDED REPORT Contribution to comprehension of image formation in confocal microscopy of cornea with Rostock cornea module
Aim: To investigate the influence of refractive index of aqueous humour on imaging of corneal endothelium in confocal microscopy. To clarify the phenomenon of dark endothelial and bright epithelial cell membranes in confocal images of corneas. Methods: Use of a novel digital confocal laser scanning microscope, a combination of the Heidelberg retina tomograph (HRT II) and the Rostock cornea modu...
متن کاملOphthoselfie: Detailed Self-imaging of Cornea and Anterior Segment by Smartphone
OBJECTIVES To describe the ophthoselfie, a method by which everyone can take detailed self-images of the cornea and anterior segment with a smartphone. MATERIALS AND METHODS A 90-diopter non-contact double aspheric lens was attached to posterior camera of the smartphone by clear tape. Images of one eye on the screen of the smartphone could be seen with the other eye in the mirror and images w...
متن کاملAnterior-segment imaging for assessment of glaucoma.
This article summarizes the physics, technology and clinical application of ultrasound biomicroscopy (UBM) and optical coherence tomography (OCT) for assessment of the anterior segment in glaucoma. UBM systems use frequencies ranging from approximately 35 to 80 MHz, as compared with typical 10-MHz systems used for general-purpose ophthalmic imaging. OCT systems use low-coherence, near-infrared ...
متن کاملThe biomechanical properties of the cornea and anterior segment parameters
BACKGROUND To investigate the biomechanical properties of the cornea measured with the Ocular Response Analyzer (ORA) and their association with the anterior segment parameters representing the geometric dimensions including the corneal volume and anterior chamber volume. METHODS A retrospective review of 1020 patients who visited the BGN Eye Clinic was done. The mean radius of the corneal cu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Ophthalmologica
سال: 2017
ISSN: 1755-375X
DOI: 10.1111/j.1755-3768.2017.02381