Rotational thromboelastometry to assess hypercoagulability in COVID-19 patients

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Narrative Review on Evaluation of Hypercoagulability State in Severe Covid-19 Patients with Background Risk Factors

Coronavirus disease (COVID-19) can induce coagulopathy at the base of sepsis-induced coagulopathy (SIC), which is an important cause of death in these patients. Cytokine storm causes imbalance in coagulation and fibrinolytic system. A combination of hypercoagulability state, decrease or inhibition of fibrinolysis and endotheliopathy causes thromboembolic events. Underlying diseases such as diab...

متن کامل

Fast interpretation of thromboelastometry in non-cardiac surgery: reliability in patients with hypo-, normo-, and hypercoagulability.

BACKGROUND Conventional coagulation test are not useful to guide haemostatic therapy in severe bleeding due to their long turn-around time. In contrast, early variables assessed by point-of-care thromboelastometry (ROTEM(®)) are available within 10-20 min and increasingly used to guide haemostatic therapy in liver transplantation and severe trauma. However, the reliability of early ROTEM(®) var...

متن کامل

Use of Protection Motivation Theory to Assess Preventive Behaviors of COVID-19

Background and purpose: The global prevalence and morbidity of Coronavirus disease 2019 (COVID-19) are high. Preventive behaviors are proven to reduce the damage caused by the disease. There is a paucity of information on determinants of preventive behaviors in response to COVID-19 in Mazandaran province, north of Iran. So, we aimed to evaluate protection motivation theory (PMT) in promoting pr...

متن کامل

Thrombin generation and rotational thromboelastometry in the healthy adult population.

AIM Published data on thrombin generation variables and their correlation with thromboelastometry in the healthy population are scarce. This study aimed at assessing thrombin generation in adults and its correlation to classical rotational thromboelastometry (ROTEM). METHODS Thrombin generation was measured in platelet-poor plasma from healthy volunteers using the calibrated automated thrombo...

متن کامل

Reference ranges for rotational thromboelastometry in male Sprague Dawley rats

Background A functional coagulation assay was used to investigate the extrinsic pathway of coagulation on citrated whole blood samples from healthy adult male Sprague Dawley rats using the mini cup and pin system. Methods Reference values for coagulation parameters from forty-three animals were calculated using data obtained from the ROTEM® delta hemostasis analyzer with the EXTEM test. Res...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Thrombosis Research

سال: 2020

ISSN: 0049-3848

DOI: 10.1016/j.thromres.2020.08.046