S2 Connector Versus Suture: Distal Coronary Anastomosis Remodeling, Patency, and Function in the Pig
نویسندگان
چکیده
منابع مشابه
S2 connector versus suture: distal coronary anastomosis remodeling, patency, and function in the pig.
BACKGROUND Anastomotic connectors could be the key to less invasive bypass surgery, including endoscopic procedures, but equivalence to conventional suturing needs to be established. A novel distal coronary connector was tested pre-clinically for safety and efficacy in comparison to conventional suturing. METHODS AND RESULTS Left internal thoracic to left anterior descending coronary artery b...
متن کاملDistal Coronary Anastomosis Remodeling, Patency, and Function in the Pig
Background—Anastomotic connectors could be the key to less invasive bypass surgery, including endoscopic procedures, but equivalence to conventional suturing needs to be established. A novel distal coronary connector was tested pre-clinically for safety and efficacy in comparison to conventional suturing. Methods and Results—Left internal thoracic to left anterior descending coronary artery byp...
متن کاملInterrupted coalescent nitinol clip versus continuous suture coronary anastomosis: a comparative endothelial function study.
BACKGROUND A new penetrating stapled anastomotic system using nitinol microclips (Coalescent Surgical U-Clip) has been developed to facilitate the construction of compliant interrupted sutures for minimally invasive and robotic surgery as well as for conventional procedures. The purpose of this study was to determine the effect of nitinol U-Clips used for coronary anastomosis in the development...
متن کاملContinuous versus interrupted suture technique in microvascular anastomosis in rats.
PURPOSE To compare the continuous and interrupted suture technique on femoral artery on rats after vessel repair and 14 days after. METHODS Twenty rats were operated randomly divided into two group matched according to the suture technique used: interrupted or continuous. We performed a femoral anastomosis on the right femoral artery. We analyzed weight, arterial caliber, anastomosis time and...
متن کاملProspective evaluation of patency and early experience utilizing an automated distal anastomosis device (C-port).
BACKGROUND : In November 2005, a new automated distal anastomotic device (C-Port) for coronary artery bypass grafting (CABG) was cleared by the FDA for use in the United States. This study represents a prospective evaluation of our early experience using the device with graft patency assessment determined by 64 slice multidetector row computed tomography angiography (64CT). MATERIALS AND METH...