چکیده
Abstract Background In TB, therapeutic drug monitoring (TDM) is recommended for linezolid; however, implementation challenging in endemic settings. Non-invasive saliva sampling using a mobile assay would increase the feasibility of TDM. Objectives To validate linezolid UV spectrophotometer. Methods The was developed NanoPhotometer NP80® and concentrations were quantified second-order derivative spectroscopy. Sample preparation involved liquid–liquid extraction saliva, saturated sodium chloride ethyl acetate at 1:1:3 (v/v/v). validated accuracy, precision, selectivity, specificity, carry-over, matrix effect, stability filters. Acceptance criteria bias coefficient variation (CV) <15% quality control (QC) samples <20% lower limit quantification (LLOQ). Results Linezolid correlated with amplitude between 250 270 nm on spectra. calibration curve linear over range 3.0 to 25 mg/L (R2 = 0.99) LLOQ mg/L. Accuracy precision demonstrated ?7.5% 2.7% CV ?5.6%. met (tested up 3 days) use filters (0.22 ?M Millex®-GV Millex®-GP). Specificity tested potential co-medications. Interferences from pyrazinamide, levofloxacin, moxifloxacin, rifampicin, abacavir, acetaminophen trimethoprim noted; minimal clinical implications dosing. Conclusions We spectrophotometric non-invasive linezolid. next step demonstrate value facilitate programmatic
منابع مشابه
Optofluidic UV-Vis spectrophotometer for online monitoring of photocatalytic reactions
On-chip integration of optical detection units into the microfluidic systems for online monitoring is highly desirable for many applications and is also well in line with the spirit of optofluidics technology-fusion of optics and microfluidics for advanced functionalities. This paper reports the construction of a UV-Vis spectrophotometer on a microreactor, and demonstrates the online monitoring...
متن کاملLinezolid: safety and efficacy monitoring
1 Kusel MMH, Kebadze T, Johnston SL, et al. Febrile respiratory illnesses in infancy and atopy are risk factors for persistent asthma and wheeze. Eur Respir J 2012; 39: 876–882. 2 Kusel MM, de Klerk NH, Kebadze T, et al. Early-life respiratory viral infections, atopic sensitization, and risk of subsequent development of persistent asthma. J Allergy Clin Immunol 2007; 119: 1105–1110. 3 Piippo-Sa...
متن کاملTherapeutic drug monitoring: linezolid too?
Numerous factors interfere with the ability to achieve optimal pharmacokinetic and pharmacodynamic targets and this has been associated with greater mortality and lower cure rates. The recent study by Zoller and colleagues examining linezolid levels in critically ill patients emphasises this point. Their study is unique in the description of the intra-patient and inter-patient variability that ...
متن کاملAdvantages of Photo Diode Array for UV-Vis Spectrophotometer
1 Preface All products are continuously being improved for better performance. Spectrometers have developed in many ways since the introduction of simple and moderately priced Spectrophotometers which were commercially available from the mid 1950’s. 1 Such improvements have enabled SCINCO to manufacture PDA type UV-Vis. Spectrophotometers. The scope and performance of conventional single channe...
متن کاملMethod Development and Validation of Metronidazole Using UV Spectrophotometer
Metronidazole in METRONIDAZOLE I.V. Infusion 500mg/100ml was determined by Spectrophotometric method. Being a very simple, reliable and sensitive method was developed and adopted to perform the analysis of METRONIDAZOLE I.V. Infusion 500mg/100ml. The Spectrophotometric method described was found to be simple, sensitive and accurate. Therefore this could be applied for the determination of METRO...