Scanning Electron Microscope Analysis of Titanium Alloy Orthodontic Implants
نویسندگان
چکیده
منابع مشابه
Titanium alloy orthodontic mini-implants: scanning electron microscopic and metallographic analyses.
Anchorage control is one of the determining factors of successful orthodontic mechanics. In mini-implants, fractures due to placement and removal have been related to implant design and titanium alloy quality. This study assessed the topography and microstructure of five brands of mini-implants (Neodent, SIN, Morelli, Conexao, Foresta Dent). Scanning electron microscopic analyses of the head, t...
متن کاملthe scanning electron microscope
it is only thirteen years since the scanning electron microscope has been available commercially. yet, even in this short period of time, this instrument has been a powerful tool in the investigation of topography, electrical and magnetic properties, crystal structure, cathodoluminescent characteristics etc. of solid specimens. today, this type of microscope has opened its place alongside the c...
متن کاملElectron Microprobe Analysis and Tissue Reaction around Titanium Alloy Spinal Implants
STUDY DESIGN A retrospective study of tissue surrounding titanium alloy spinal implants was performed using histological and electron microprobe analysis. PURPOSE To identify the metal debris generated by spinal implants, and then to evaluate the electron microprobe analysis results and the histological response of soft tissue surrounding the spinal implants. OVERVIEW OF LITERATURE Microsco...
متن کاملComparison of mechanical and biological properties of zirconia and titanium alloy orthodontic micro-implants
OBJECTIVE The aim of this study was to compare the initial stability as insertion and removal torque and the clinical applicability of novel orthodontic zirconia micro-implants made using a powder injection molding (PIM) technique with those parameters in conventional titanium micro-implants. METHODS Sixty zirconia and 60 titanium micro-implants of similar design (diameter, 1.6 mm; length, 8....
متن کاملTitanium alloy mini-implants for orthodontic anchorage: immediate loading and metal ion release.
Removable osseointegrated titanium mini-implants were successfully used as anchorage devices in orthodontics. The early load is necessary to simplify the mini-implant methodology, but can lead to failure during osseointegration. The Ti-6Al-4V alloy was used instead of commercially pure Ti due to its superior strength. However, the corrosion resistance is low, allowing for metal ion release. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Materiale Plastice
سال: 2017
ISSN: 0025-5289,2668-8220
DOI: 10.37358/mp.17.2.4848