Scanning System Using Transmission Line Type Thin Film Sensor
نویسندگان
چکیده
منابع مشابه
Flexible Tactile Sensor Using Polyurethane Thin Film
A novel capacitive tactile sensor using a polyurethane thin film is proposed in this paper. In previous studies, capacitive tactile sensors generally had an air gap between two electrodes in order to enhance the sensitivity. In this study, there is only polyurethane thin film and no air gap between the electrodes. The sensitivity of this sensor is higher than the previous capacitive tactile sen...
متن کاملUltrasensitive, fast, thin-film differential scanning calorimeter
The equipment for an ultrasensitive, fast, thin-film differential scanning calorimetry @~TDSC! or nanocalorimetry# technique is described. The calorimetric cell ~;0.30 cm! operates by applying a short ~;10 ms! dc current pulse ~;10 mA! to a thin ~;50 nm! patterned metal strip, which is supported by a thin ~;50 nm! SiNx membrane. The calorimeter operates at high heating rates ~15–200 K/ms! and i...
متن کاملThin Film Thickness Measurement Using Conduction and Infrared Transmission
Many applications in a diverse demographic of engineering fields require knowledge of the thickness of thin films and coatings. An example of some applications for which thin film thickness is critical are semiconductors, optics, and protective coatings. There are various methods for measuring thin film thickness, however, many of them are destructive, or are only capable of measuring thickness...
متن کاملSelf-powered thin-film motion vector sensor
Harnessing random micromeso-scale ambient energy is not only clean and sustainable, but it also enables self-powered sensors and devices to be realized. Here we report a robust and self-powered kinematic vector sensor fabricated using highly pliable organic films that can be bent to spread over curved and uneven surfaces. The device derives its operational energy from a close-proximity triboele...
متن کاملA Micro-Fabricated Force Sensor Using an All Thin Film Piezoelectric Active Sensor
The ability to measure pressure and force is essential in biomedical applications such as minimally invasive surgery (MIS) and palpation for detecting cancer cysts. Here, we report a force sensor for measuring a shear and normal force by combining an arrayed piezoelectric sensors layer with a precut glass top plate connected by four stress concentrating legs. We designed and fabricated a thin f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Magnetics Society of Japan
سال: 2011
ISSN: 1882-2932,1882-2924
DOI: 10.3379/msjmag.1102r007