Scanning Transmission Ion Microscopy and Diffraction Imaging
نویسندگان
چکیده
منابع مشابه
Radial Distribution Function Imaging by Diffraction Scanning Electron Microscopy
1. Institut für Nanotechnology (INT), Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen, Germany 2. Helmholtz-Institute Ulm for Electrochemical Energy Storage (HIU), Karlsruhe Institute of Technology (KIT), 89081 Ulm, Germany 3. Karlsruhe Nano Micro Facility (KNMF), Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen, Germany 4. Herbert Gleiter Institut...
متن کاملScanning Ion Conductance Microscopy
Scanning ion conductance microscopy (SICM) is an imaging technique, measuring conductance through a nanometer-sized pipette tip opening that is brought close to a sample surface submerged in electrolyte solution. In combination with an integrated shear force distance control, the local ion conductance can be measured independently of and simultaneously with topography. The design of a shear-fo...
متن کاملScanning Ion Conductance Microscopy
Scanning ion conductance microscopy (SICM) is an imaging technique, measuring conductance through a nanometer-sized pipette tip opening that is brought close to a sample surface submerged in electrolyte solution. In combination with an integrated shear force distance control, the local ion conductance can be measured independently of and simultaneously with topography. The design of a shear-fo...
متن کاملScanning Ion Conductance Microscopy
Scanning ion conductance microscopy (SICM) is an imaging technique, measuring conductance through a nanometer-sized pipette tip opening that is brought close to a sample surface submerged in electrolyte solution. In combination with an integrated shear force distance control, the local ion conductance can be measured independently of and simultaneously with topography. The design of a shear-fo...
متن کاملX-Ray Diffraction and Scanning Probe Microscopy
Diffraction can occur when electromagnetic radiation interacts with a periodic structure whose repeat distance is about the same as the wavelength of the radiation. Visible light, for example, can be diffracted by a grating that contains scribed lines spaced only a few thousand angstroms apart, about the wavelength of visible light. X-rays have wavelengths on the order of angstroms, in the rang...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2010
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927610053791