Scatter correction for positron emission mammography.

In this paper we present a scatter correction method for a regularized list mode maximum likelihood reconstruction algorithm for the positron emission mammograph (PEM) that is being developed at our laboratory. The scatter events inside the object are modelled as additive Poisson random variables in the forward model of the reconstruction algorithm. The mean scatter sinogram is estimated using ...

متن کامل

Clinical utility of positron emission mammography.

Several imaging modalities have been introduced over recent years to better screen for and stage breast cancer. Positron emission mammography (PEM) has been approved by the US Food and Drug Administration and introduced into clinical use as a diagnostic adjunct to mammography and breast ultrasonography. PEM has higher resolution and a more localized field of view than positron emission tomograp...

متن کامل

Scatter correction in digital mammography based on image deconvolution.

X-ray scatter is a major cause of nonlinearity in densitometry measurements using digital mammography. Previous scatter correction techniques have primarily used a single scatter point spread function to estimate x-ray scatter. In this study, a new algorithm to correct x-ray scatter based on image convolution was implemented using a spatially variant scatter point spread function which is energ...

متن کامل

Positron emission mammography (PEM): reviewing standardized semiquantitative method

PURPOSE To validate semiquantitative analysis of positron emission mammography (PEM). METHODS Fifty women with histologically confirmed breast lesions were retrospectively enrolled. Semiquantitative uptake values (4 methods), the maximum PEM uptake value (PUVmax), and the lesion-to-background (LTB) value (3 methods) were measured. LTB is a ratio of the lesion's PUVmax to the mean background; ...

متن کامل

Respiratory Motion Correction in Positron Emission Tomography

In this thesis, we develop a motion correction method to overcome the degradation of image quality introduced by respiratory motion in positron emission tomography (PET), so that diagnostic performance for lung cancer can be improved. Lung cancer is currently the most common cause of cancer death both in the UK and in the world. PET/CT, which is a combination of PET and CT, providing clinicians...

متن کامل