Investigation and Analysis of Empirical Field Seismic Damage to Bottom Frame Seismic Wall Masonry Structure

To understand the seismic damage characteristics of bottom frame-wall buildings and to study their seismic performance, the seismic damage outcomes of  bottom frame-wall structures in Du jiang weir by the Wen chuan earthquake on May 12,2008, China were field observed and studied. The assesment of the seismic damage to the bottom frame-wall masonry in Du jiang weir urban showed that the damage t...

متن کامل

Empirical Seismic Vulnerability and Damage of Bottom Frame Seismic Wall Masonry Structure: A Case Study in Dujiangyan (China) Region

In order to understand the seismic performance and mechanism of bottom frame seismic wall masonry structure (BFSWMS) and its vulnerability in empirical seismic damage, based on the statistical and numerical analysis of the field seismic damage observation data of 2178 Dujiangyan structures in the Wenchuan great earthquake urban of China on May 12, 2008, a non-linear function model between the s...

متن کامل

Simplified indexes for the seismic vulnerability of ancient masonry buildings

This paper presents a contribution for the safety assessment of historical masonry buildings under seismic loading. Three different simplified safety indexes (in-plan area ratio, area to weight ratio and base shear ratio) are analyzed, taking into account a large sample of fifty-eight Portuguese churches. The sample of building has been organized according to the seismic zonation, from high to ...

متن کامل

Damage Accumulation in Unreinforced Masonry Due to Seismic Loading

Masonry has low cohesive strength and is susceptible to the brittle failure, when subjected to induced tensile stresses. It fails due to lateral tensile stresses even when masonry prisms are tested in uni-axial static compression and the stress-strain curve remains almost linear up to failure. Although masonry normally resists compressive forces, under lateral in-plane cyclic loads some parts o...

متن کامل

Seismic Behavior and Design of Wall–EDD–Frame Systems

Walls and frames have different deflection lines and, depending on the seismic mass they support, may often possess different natural periods. In many cases, wall–frame structures present an advantageous behavior. In these structures, the walls and the frames are rigidly connected. Nevertheless, if the walls and the frames were not rigidly connected, an opportunity for an efficient passive cont...