Seismic Performance of Fully Prefabricated L-Shaped Shear Walls with Grouted Sleeve Lapping Connectors under High Axial Compression Ratio

نویسندگان

چکیده

The grouted sleeve lapping connector called the APC has advantages of high fault tolerance, convenient construction, compacted grouting, and low cost, together with realizing full prefabrication vertical components. In this paper, a quasi-static test two fully prefabricated L-shaped walls connected types cast-in-place wall was carried out under axial compression ratio (0.5) to compare their seismic performance. results indicated that connectors effectively transferred rebar stress in walls, failure modes final crack distribution were basically identical. occurred at root limb, while top due constraint sleeve. bearing capacity, stiffness, ductility, energy dissipation specimen by type-I comparable wall, type-II showed greater ductility. Finally, some suggestions for design components are proposed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental study of grouted sleeve lapping connector under tensile load

The performance of the grouted sleeve lapping connector that is used to connect reinforcement bars in a precast concrete structure is studied. A total of 63 specimens, varying in bar diameter and lap length, were tested under tensile load. The failure modes, ultimate tensile strength values and load-displacement curves of the specimens are discussed in the study. Two equations are proposed for ...

متن کامل

Experimental Study on New-typed Prefabricated Shear Walls with Vertical Joint Under Different Shear Span Ratio

The results show that the shear span ratio has significant effect on the mechanical behavior of the new-typed prefabricated shear walls, and the new-typed prefabricated shear walls have good ductility, all the ductility factors are greater than 4.0. The study also proves that the construction of the vertical joint is reasonable and its connection property is reliable. The vertical joint which c...

متن کامل

Seismic Behavior of the Partially Prefabricated Laminated RC Walls Under Different Axial Ratios

The partially prefabricated laminated (RC) walls mentioned is this kind of seismic prevention element with part prefabricated concrete plate and cast in place concrete plate. 4 typical laminated walls without openings, 4 laminated walls with openings, and 1 common cast-in-place RC walls were tested under cyclic test. The seismic behaviour were analysed by the finite element software based on th...

متن کامل

Shear Capacity of C-Shaped and L-Shaped Angle Shear Connectors

This paper investigates the behaviour of C-shaped and L-shaped angle shear connectors embedded in solid concrete slabs. An effective finite element model is proposed to simulate the push out tests of these shear connectors that encompass nonlinear material behaviour, large displacement and damage plasticity. The finite element models are validated against test results. Parametric studies using ...

متن کامل

Experimental Study on Shear Behavior of Mid-rise Assembled Monolithic Concrete Shear Walls with Varying Axial Compression Ratio

The result showed that the brittle failure was extinct, and the new-type shear walls had good deformability whose ductility factors were over 4.3. The axial compression ratio had significant influence on the mechanical properties of the new-type shear walls. As the increscent of the axial compression ratio, the shear capacity and initial stiffness were improved, but the energy-dissipating capac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2023

ISSN: ['2076-3417']

DOI: https://doi.org/10.3390/app13042301