Seismic resistance evaluation of multi-story buildings using the modern LIRA-SAPR SP
نویسندگان
چکیده
This article presents the results of evaluating seismic resistance high-rise buildings on real records accelogram and regulatory documents using LIRA-SAPR SP. The maximum minimum values bending moments, longitudinal forces, shear stresses are determined, most vulnerable areas where cracking in load-bearing structures is possible determined. It was found that force factors arising under action turned out to be 2 times less than obtained from data based documents. Along with this, it calculation for according accelerograms showed higher building, greater magnitude displacements, moments forces upper floors buildings. requires development appropriate measures reduce vibrations multi-story
منابع مشابه
Seismic Design of Multi-story Buildings with Metallic Structural Fuses
Seismic design relies on inelastic deformations through hysteretic behavior. However, this translates into damage on structural elements, permanent system deformations following an earthquake, and possibly high cost for repairs. An alternative design approach is to concentrate damage on disposable and easy to repair structural elements (i.e., “structural fuses”), while the main structure is des...
متن کاملSeismic design of multi - story cold - formed steel buildings : the CFS - NEES archetype building
Lightweight cold-formed steel (CFS) framing is an effective building solution for low and mid-rise structures. However, systems level response and component contributions as well as their interactions such as those from lateral-load resisting systems, floor diaphragms, studs to track connections, etc., are not fully understood. Existing building codes for the CFS frame buildings are based solel...
متن کاملProbabilstic Seismic Risk Evaluation of Rc Buildings
As more and more emphasis is being laid on non-linear analysis of RC framed structures subjected to earthquake excitation, the research and development on both non-linear static (pushover) analysis as well as nonlinear dynamic (time history)analysis is in the forefront. Due to prohibitive computational time and efforts required to perform a complete nonlinear dynamic analysis, researchers and d...
متن کاملSound insulation in multi-story timber buildings
During on an extensive investigation of a multi-story timber building with light-frame construction, several stages of the building process and their impact on sound transmission were observed. The sound insulation properties of the building components were measured before and while the buildings were occupied. Furthermore, interviews with the occupants were conducted. This procedure made it po...
متن کاملSeismic Performance of Torsionally Stiff and Flexible Single Story Buildings Designed Based on Iranian Seismic Code(Standard 2800)
This paper examines differences in performances of a range of torsionally stiff and flexible single story buildings designed with the provisions of Iranian Standard 2800. Seismic nonlinear dynamic time history behavior of eight building models subjected to seven horizontal bi-directional design spectra compatible ground motions are investigated. These models cover a wide range of very torsional...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2023
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202340207021