Seismic Retrofitting Effects of Retrofitted Unreinforced Masonry Walls Using Metal Laths and Steel Plates

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective stiffness of unreinforced brick masonry walls

Code design of Unreinforced Masonry (URM) buildings is based on elastic analysis, which requires as input parameter the effective stiffness of URM walls. Current approaches estimate the effective stiffness as fixed ratio of the gross sectional stiffness but comparisons with experimental results have shown that this does not yield satisfactory predictions. In this paper, a recently developed ana...

متن کامل

Effect of Unreinforced Masonry Infill Walls on Seismic Performance of Reinforced Concrete Framed Structures

Unreinforced Masonry infill walls (URM) are commonly used in the Reinforced Concrete (RC) framed structures as interiors and exteriors partition walls. Although they usually are not considered in the structural analysis and design, their influence on the seismic performance of the framed structures is significant. A common practice in the modern and old RC buildings is to remove the URM walls i...

متن کامل

Retrofitting Masonry Walls with Carbon Mesh

Static-cyclic shear load tests and tensile tests on retrofitted masonry walls were conducted at UAS Fribourg for an evaluation of the newly developed retrofitting system, the S&P ARMO-System. This retrofitting system consists of a composite of carbon mesh embedded in a specially adapted high quality spray mortar. It can be applied with established construction techniques using traditional const...

متن کامل

Damage Accumulation in Unreinforced Masonry Due to Seismic Loading

Masonry has low cohesive strength and is susceptible to the brittle failure, when subjected to induced tensile stresses. It fails due to lateral tensile stresses even when masonry prisms are tested in uni-axial static compression and the stress-strain curve remains almost linear up to failure. Although masonry normally resists compressive forces, under lateral in-plane cyclic loads some parts o...

متن کامل

Scaling unreinforced masonry for reduced-scale seismic testing

When testing multi-storey structures, most testing facilities require the testing of a reduced-scale model. A literature review on tests of scaled masonry structural components revealed that scaling of masonry was rather challenging and often significant differences in stiffness, strength and failure mechanisms between the different sized masonry were reported. This paper addresses the scaling ...