SEISMIC RETROFITTING OF SINGLE-STORY RC PRECAST BUILDINGS THROUGH A NOVEL METALLIC HYSTERETIC DEVICE
نویسندگان
چکیده
منابع مشابه
Seismic Retrofitting RC Structures with Precast Prestressed Concrete Braces- ABAQUS FEA Modeling
Precast prestreesed concrete braces are a new method for seismic strength of Concrete Structures which has the following benefits: a) no wet concrete work in construction site b) No bolt or anchorage to the existing frame c) easy to apply d) short construction period e) low construction cost, to evaluate seismic performance of strengthened structure a model consist of existing frame and concret...
متن کاملSeismic Design of Multi-story Buildings with Metallic Structural Fuses
Seismic design relies on inelastic deformations through hysteretic behavior. However, this translates into damage on structural elements, permanent system deformations following an earthquake, and possibly high cost for repairs. An alternative design approach is to concentrate damage on disposable and easy to repair structural elements (i.e., “structural fuses”), while the main structure is des...
متن کاملEvaluation of the Seismic Response of Single-Story RC Frames under Biaxial Earthquake Excitations
This paper summarizes the lessons learned from a full-scale test on two RC frame prototypes that have recently been tested on LNEC shaking-table using four pairs of biaxial synthetic ground motion records during 15WCEE Conference (2012). The reference structures are two single-story RC frames which are geometrically identical but with different reinforcement details. The simplified inelastic mo...
متن کاملProbabilstic Seismic Risk Evaluation of Rc Buildings
As more and more emphasis is being laid on non-linear analysis of RC framed structures subjected to earthquake excitation, the research and development on both non-linear static (pushover) analysis as well as nonlinear dynamic (time history)analysis is in the forefront. Due to prohibitive computational time and efforts required to perform a complete nonlinear dynamic analysis, researchers and d...
متن کاملSeismic Performance of Torsionally Stiff and Flexible Single Story Buildings Designed Based on Iranian Seismic Code(Standard 2800)
This paper examines differences in performances of a range of torsionally stiff and flexible single story buildings designed with the provisions of Iranian Standard 2800. Seismic nonlinear dynamic time history behavior of eight building models subjected to seven horizontal bi-directional design spectra compatible ground motions are investigated. These models cover a wide range of very torsional...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: COMPDYN Proceedings
سال: 2021
ISSN: ['2623-3347']
DOI: https://doi.org/10.7712/120121.8826.19461