Selection of Parameters for Accumulating Layer of Solar Walls with Transparent Insulation

نویسندگان

چکیده

One of the strategies to improve energy performance buildings may be use passive solar systems with transparent insulation. In article, a numerical model wall (SW) insulation (TI) obtained using method elementary balances is presented. On this basis, simulations behavior SW honeycomb made modified cellulose acetate were performed for 4 different climatic conditions in Europe (Stockholm, Warsaw, Paris, and Rome). For each location, calculations carried out three TI thickness values (48, 88, 128 mm), thermal diffusivity accumulating layer (AL) ranging from 4.32 × 10?7 8.43 m2/s, its 0.1 0.5 m. The purpose was select appropriate material AL conditions. following solutions proved most favorable: Stockholm: TI—thk. mm, AL—sand-lime blocks, thk. 25 cm; Warsaw: 27 Paris: 88 AL—solid ceramic brick, Rome: 48 29 cm.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the test for adverse selection in life insurance market: the case of mellat insurance company

انتخاب نامساعد یکی از مشکلات اساسی در صنعت بیمه است. که ابتدا در سال 1960، توسط روتشیلد واستیگلیتز مورد بحث ومطالعه قرار گرفت ازآن موقع تاکنون بسیاری از پژوهشگران مدل های مختلفی را برای تجزیه و تحلیل تقاضا برای صنعت بیمه عمر که تماما ناشی از عدم قطعیت در این صنعت میباشد انجام داده اند .وهدف از آن پیدا کردن شرایطی است که تحت آن شرایط انتخاب یا کنار گذاشتن یک بیمه گزار به نفع و یا زیان شرکت بیمه ...

15 صفحه اول

technical and legal parameters for determination of river boundary,( case study haraz river)

چکیده با توسعه شهر نشینی و دخل و تصرف غیر مجاز در حریم رودخانه ها خسارات زیادی به رودخانه و محیط زیست اطراف آن وارده می شود. در حال حاضر بر اساس آئین نامه اصلاح شده بستر و حریم رودخانه ها، حریم کمی رودخانه که بلافاصله پس از بستر قرار می گیرد از 1 تا20 متر از منتهی الیه طرفین بستر رودخانه تعیین، که مقدار دقیق آن در هر بازه از رودخانه مشخص نیست. در کشورهای دیگر روشهای متفاوتی من جمله: درصد ریسک...

15 صفحه اول

Determination of Optimum Insulation Thickness for Building Walls in Iran Using Life Cycle Cost Analysis

Air-Conditioning (AC) systems are responsible for a considerable portion of the energy consumption in buildings located in high cooling load requiring regions of Iran. In addition, the heat flow through the buildingschr('39') external walls plays a major role in cooling load estimations for the countrychr('39')s hot regions. Therefore, application of insulation materials in external walls has g...

متن کامل

Comparative Analysis of Active and Passive Solar Heating Systems with Transparent Insulation

The objective of this research is to achieve a high solar fraction in social housing, for which investment costs are strictly limited. Six houses have been built in the east of France: two with active (solar collectors) and four with passive (Trombe walls) solar heating systems. Two types of transparent covers are compared: a capillary structure and a simpler polycarbonate plate. The project wa...

متن کامل

Automatic Verification of Functions with Accumulating Parameters

Proof by mathematical induction plays a crucial role in reasoning about functional programs. A generalization step often holds the key to discovering an inductive proof. We present a generalization technique which is particularly applicable when reasoning about functional programs involving accumulating parameters. We provide empirical evidence for the success of our technique and show how it i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2021

ISSN: ['1996-1073']

DOI: https://doi.org/10.3390/en14051283