Selective Electrosyntheses on Chemically Modified Electrode. II. Anodic Chlorination of Anisole with Cyclodextrin on Electrode Surfaces and in Solution

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrocatalytic Oxidation of Vitamin B6 on a Chemically Modified Electrode

The electrocatalytic oxidation of vitamin B6 (pyridoxine hydrochloride) was demonstrated on a Nafion/lead ruthenate pyrochlore modified electrode (designated as NCME) by cyclic voltammetry. The catalytic activity of vitamin B6 was explored in terms of the higher oxidation state of ruthenium species, i.e., Py-Ru/Ru in the pyrochlore network (Py). The mediated mechanism was derived by Michaelis-M...

متن کامل

Simultaneous Determination of Hg(II), Cd(II), Pb(II) and Zn(II) by Anodic Stripping Voltammetry using Modified Carbon Paste Ionic Liquid Electrode

In the presented study, CuO-CoO-MnO/SiO2 nanocomposite was synthesis by Cu(II), Co(II), Mn(II), with 1:1:1 mole ratio and Tetraethyl orthosilicate. azo–azomethine 1-(3-imino-4-hydroxophenylazo-4-nitrobenzene)-4-methyl phenol (L) was synthesized and used as a ligand for capturing the metal ions. Also, 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)imide was applied as the i...

متن کامل

Lead(II)-selective electrode based on phenyl disulfide.

A PVC membrane electrode for lead ions based on phenyl disulfide as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of 29.3 +/- 0.7 mV/decade and a linear range of 2.0 x 10(-6)-1.0 x 10(-2) M for Pb(NO3)2. The limit of detection is 1.2 x 10(-6) M. It has a response time of 45 s and can be used for at least fifty days without any divergence in potential. The pro...

متن کامل

Cu(II) Ion- Selective Membrane Electrode Based on bis(N-salicylidene-3,3'-diamino diphenyl) sulfone

In order to study the Cu(II) ion selective electrode, an optimized membrane was prepared by mixing of 30 mg of PVC powdered, 5 mg of considered ionophore, 60 mg of plasticizer and 5 mg of additive. The sensor showed a near Nernstian response for Cu(II) ions over a concentration range from 1.0×0-6 –1.0×0-2 M with a slope of 28.90.5 mV per concentration decade with a working pH range of 3.5-6.3. ...

متن کامل

Sn (II) Ion- Selective Membrane Electrode based on Dibenzo-18-Crown-6

We found that dibenzo-18-crown-6 (DB18C6) can be used as an ionophore to make a tin (II)-ionselectivemembrane electrode. The electrode exhibits a near Nernstian response for Sn2+ ions over aconcentration range from 1.0× 10-6 – 1.0× 10-2 M with a slope of 27.5 ± 0.6 mV per concentration decadein an acidic solution (pH=1). The limit of detection was 8.0× 10-7 M. It has a response time of < 20s an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Bulletin of the Chemical Society of Japan

سال: 1979

ISSN: 0009-2673,1348-0634

DOI: 10.1246/bcsj.52.3692