Selenium-coated carbon electrode for anodic stripping voltammetric determination of copper(II)

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anodic Stripping Voltammetric Determination of Gold on a Polyvinylferrocene Coated Glassy Carbon Electrode

The anodic stripping voltammetric determination of gold was accomplished on a chemically modified glassy carbon electrode in a solution containing chloride ions. A modifying polymer, polyvinylferrocene, was coated by immersing the glassy carbon surface in its solution in methylene chloride followed by solvent evaporation. Tetrahalo complexes of gold, tetrachloroaurate(III) and tetrabromoaurate(...

متن کامل

Anodic Stripping Voltammetric Determination of Nitrite Using Carbon Paste Electrode Modified with Chitosan

A simple method for anodic stripping voltammetric determination of nitrite using carbon paste electrode modified with biomolecular chitosan, is described. In this method, the electrode is activated electrochemically by scanning 5 replicates over the potential range from +500 to +1400 mV immersing in 0.5 M HCl solution. Following this step, the nitrite sample containing 0.1 M KCl is pre-concentr...

متن کامل

Anodic Voltammetric determination of gemifloxacin using screen-printed carbon electrode

The electrochemical oxidation behavior and voltammetric assay of gemifloxacin were investigated using differential-pulse and cyclic voltammetry on a screen-printed carbon electrode. The effects of pH, scan rates, and concentration of the drug on the anodic peak current were studied. Voltammograms of gemifloxacin in Tris-HCl buffer (pH 7.0) exhibited a well-defined single oxidation peak. A diffe...

متن کامل

Differential pulse anodic stripping voltammetric determination of traces of copper with a tobramycin-Nafion modified electrode.

A Nafion-modified glassy carbon electrode incorporated with tobramycin for the voltammetric stripping determination of Cu2+ has been explored. The electrode was fabricated by tobramycin containing Nafion on the glassy carbon electrode surface. The modified electrode exhibited a significantly increased sensitivity and selectivity for Cu2+ compared with a bare glassy carbon electrode and the Nafi...

متن کامل

Ultra-Sensitive Anodic Stripping Voltammetry for the Determination of Xanthine at a Glassy Carbon Electrode

An electrochemical anodic stripping procedure for ultra-trace assay of xanthine in Cu2þ solution at a glassy carbon electrode (GCE) is described. Cyclic voltammetry was used to characterize the nature of the process taking place at the GCE. The anodic stripping response in the presence of Cu2þ, at 150 mV (peak I) and 600 mV (peak II), is evaluated with respect to various experimental and instru...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Microchimica Acta

سال: 2009

ISSN: 0026-3672,1436-5073

DOI: 10.1007/s00604-009-0221-8