Semiactive Control of Seismic Isolation System Using Mechatro Damper.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Semiactive Neuro-control for Seismically Excited Structure Using Mr Damper

A new semiactive control strategy for seismic response reduction using a neurocontroller and a magnetorheological (MR) fluid damper is proposed. The proposed control system adopts a clipped algorithm which induces the MR damper to generate approximately the desired control force. The improved neuro-controller, which was developed by employing the training algorithm based on a cost function and ...

متن کامل

Seismic control of smart base isolated buildings with new semiactive variable damper

A new semiactive independently variable damper, SAIVD, is developed and shown to be effective in achieving response reductions in smart base isolated buildings in near fault earthquakes. The semiactive device consists of four linear visco-elastic elements, commonly known as Kelvin–Voigt elements, arranged in a rhombus configuration. The magnitude of force in the semiactive device can be adjuste...

متن کامل

Seismic Response Reduction of a Building Using Top-Story Isolation System with MR Damper

In this study, the adaptability of a semi-active top-story isolation system with an MR damper for reduction of seismic responses of tall buildings has been investigated. To this end, a 20-story building structure was selected as an example. Low damping elastomeric bearings and an MR damper were used to compose a smart top-story isolation system. Artificial earthquakes generated based on design ...

متن کامل

Semiactive Control System based on MR Damper for Suppressing Vibration of Stay Cable under Wind Load

This paper investigates the performance of the semiactive control system based on magnetorheological fluid (MR) dampers for suppressing excessive vibration of stay cable installed in cable-stayed bridges under wind load. The cable model is extracted from a 156.3 m long stay cable with high tension. The external wind load is generated from the widely used wind load spectrum such as the Kaimal sp...

متن کامل

Study and Comparison of Seismic Behaviour of Isolator-Damper Hybrid Control System with Conventional Structural Systems

In this paper, in addition to introduce a hybrid structural system contained local isolators and dampers, its behavior and functional capabilities were studied on a conventional structure. For this purpose, an RC frame building with six-story was designed based on valid codes and then, in four cases based on the number of spans, it was split into two separate adjacent frames. Base isolation was...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C

سال: 1995

ISSN: 0387-5024,1884-8354

DOI: 10.1299/kikaic.61.1308