Sensitivity of sodium iodide cryogenic scintillation-phonon detectors to WIMP signals

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimizing WIMP directional detectors

We study the dependence of the exposure required to directly detect a WIMP directional recoil signal on the capabilities of a directional detector. Specifically we consider variations in the nuclear recoil energy threshold, the background rate, whether the detector measures the recoil momentum vector in 2 or 3 dimensions and whether or not the sense of the momentum vector can be determined. We ...

متن کامل

Limits on WIMP dark matter using scintillating CaWO 4 cryogenic detectors with active background suppression

We present first significant limits on WIMP dark matter by the phonon-light technique, where combined phonon and light signals from a scintillating cryogenic detector are used. Data from early 2004 with two 300 g CRESST-II prototype detector modules are presented, with a net exposure of 20.5 kg days. The modules consist of a CaWO4 scintillating “target” crystal and a smaller cryogenic light det...

متن کامل

Fast digitizing techniques applied to scintillation detectors

A 200 MHz 12-bit fast transient recorder card has been used for the digitization of pulses from photomultipliers coupled to organic scintillation detectors. Two modes of operation have been developed at ENEA-Frascati: a) continuous acquisition up to a maximum duration of ∼ 1.3 s corresponding to the full on-board memory (256 MSamples) of the card: in this mode, all scintillation events are reco...

متن کامل

WIMP dark matter detectors above 100 K

Of key motivation in the development of detector strategies in the search for Weakly Interacting Massive Particles (WIMPs) is the need to maximize the information obtainable from the expected elastic recoil events so that these can be distinguished from background interactions and systematic errors can be controlled. Low temperature techniques may provide one route. However, most of the detecto...

متن کامل

Scintillation detectors for x-rays

Recent research in the field of phosphor and scintillator materials and related detectors is reviewed. After a historical introduction the fundamental issues are explained regarding the interaction of x-ray radiation with a solid state. Crucial parameters and characteristics important for the performance of these materials in applications, including the employed measurement methods, are describ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2016

ISSN: 1742-6588,1742-6596

DOI: 10.1088/1742-6596/718/4/042015