Sensorless predictive current control with a charge balance current estimator for boost converters based on discrete‐time model considering current ripple

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensorless Motor Drives with Predictive Current Control

Hardware complexity of a motor drive can be reduced by estimating controls rather than measuring using sensors. In this way the corresponding sensors are eliminated and the system becomes more robust. This article is about speed control of a sensor less induction motor with predictive current controller technique. This particular speed control technique does not require direct measurements of m...

متن کامل

DCM Frequency Control Algorithm for Multi-Phase DC-DC Boost Converters for Input Current Ripple Reduction

In this paper, a discontinuous conduction mode (DCM) frequency control algorithm is proposed to reduce the input current ripple of a multi-phase interleaved boost converter. Unlike conventional variable duty and constant frequency control, the proposed algorithm controls the switching frequency to regulate the output voltage. By fixing the duty ratio at 1/N in the N-phase interleaved boost conv...

متن کامل

A Grid Connected Transformerless Inverter and its Model Predictive Control Strategy with Leakage Current Elimination Capability

This paper proposes a new single phase transformerless Photovoltaic (PV) inverter for grid connected systems. It consists of six power switches, two diodes, one capacitor and filter at the output stage. The neutral of the grid is directly connected to the negative terminal of the source. This results in constant common mode voltage and zero leakage current. Model Predictive Controller (MPC) tec...

متن کامل

A Voltage Sensorless Control Method to Balance the Input Current of the Boost

This paper proposes a control method that can balance the input current of the three phase, three wire, Boost rectifier under unbalanced input voltage condition. The control objective is to operate the rectifier in the high power factor mode under normal operating condition but to give ovemdmg priority to the current balance function in case of unbalance in the input voltages. The inner loop im...

متن کامل

A Current-Based Output Feedback Sliding Mode Control for Speed Sensorless Induction Machine Drive Using Adaptive Sliding Mode Flux Observer

This paper presents a new adaptive Sliding-Mode flux observer for speed sensorless and rotor flux control of three-phase induction motor (IM) drives. The motor drive is supplied by a three-level space vector modulation (SVM) inverter. Considering the three-phase IM Equations in a stator stationary two axis reference frame, using the partial feedback linearization control and Sliding-Mode (SM) c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IET Power Electronics

سال: 2018

ISSN: 1755-4543,1755-4543

DOI: 10.1049/iet-pel.2018.5051