Shaking table testing for masonry infill walls: unreinforced versus reinforced solutions
نویسندگان
چکیده
منابع مشابه
Effect of Unreinforced Masonry Infill Walls on Seismic Performance of Reinforced Concrete Framed Structures
Unreinforced Masonry infill walls (URM) are commonly used in the Reinforced Concrete (RC) framed structures as interiors and exteriors partition walls. Although they usually are not considered in the structural analysis and design, their influence on the seismic performance of the framed structures is significant. A common practice in the modern and old RC buildings is to remove the URM walls i...
متن کاملRetrofit of Un-Reinforced Infill Masonry Walls with FRP
This paper describes an experimental program that deals with retrofitting of infill un-reinforced masonry walls (URM) with Fiber Reinforced Polymer (FRP). The primary objective of this research is to develop a retrofit strategy that while economical will minimize the influence of the retrofit on the overall performance of structural frames in predominant seismic regions. Allowing some damage to...
متن کاملEffective stiffness of unreinforced brick masonry walls
Code design of Unreinforced Masonry (URM) buildings is based on elastic analysis, which requires as input parameter the effective stiffness of URM walls. Current approaches estimate the effective stiffness as fixed ratio of the gross sectional stiffness but comparisons with experimental results have shown that this does not yield satisfactory predictions. In this paper, a recently developed ana...
متن کاملTesting unreinforced masonry structures at reduced scale
When testing multi-story structures on a shaking table, most testing facilities require a reduced scale model. Producing scale test units at small scale is particularly challenging for unreinforced masonry structures. Previous work by other researchers showed that scaling of units and mortar joints is mandatory in order to obtain for the reduced scale masonry failure modes, which are similar to...
متن کاملDynamic testing of a four-storey building with reinforced concrete and unreinforced masonry walls: prediction, test results and data set
This paper presents the results of a series of shake-table tests on a half-scale, four-storey building with reinforced concrete and unreinforced masonry walls. Due to the lack of reference tests, the seismic behaviour of such mixed structures is poorly understood. The test unit was subjected to several runs of increasing intensity yielding performance states between minor damage and near collap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Earthquake Engineering & Structural Dynamics
سال: 2016
ISSN: 0098-8847