Shape Deformation in Two-Dimensional Electrical Impedance Tomography
نویسندگان
چکیده
منابع مشابه
Applications of Electrical Impedance Tomography in Neurology
Introduction: Electrical impedance tomography (EIT) is a non-invasive technique utilized in various medical applications, including brain imaging and other neurological diseases. Recognizing the physiological and anatomical characteristics of organs based on their electrical properties is one of the main applications of EIT, as each variety of tissue structure has its own electrical characteris...
متن کاملElectrical Impedance Tomography by Elastic Deformation
This paper presents a new algorithm for conductivity imaging. Our idea is to extract more information about the conductivity distribution from data that have been enriched by coupling impedance electrical measurements to localized elastic perturbations. Using asymtotics of the elds in the presence of small volume inclusions, we relate the pointwise values of the energy density to the measured d...
متن کاملElectrical Impedance Tomography: from Topology to Shape
A level set based shape and topology optimization approach to electrical impedance tomography (EIT) problems with piecewise constant conductivities is introduced. The proposed solution algorithm is initialized by using topological sensitivity analysis. Then it relies on the notion of shape derivatives to update the shape of the domains where the conductivity takes its different values.
متن کاملThree- dimensional Effects in Electrical Impedance Tomography
An investigation of 3-dimesional (3D) effects on electrical impedance tomography is reported. 3D effects in measurement, simulation and analytical models are described. A 3D attenuation range (75% attenuation) from the sensing plane is suggested as one third of process vessel’s diameter. The imaging trajectory of an axially moving object is found towards the central axis of a process vessel whe...
متن کاملMonotonicity-Based Shape Reconstruction in Electrical Impedance Tomography
Current-voltage measurements in electrical impedance tomography (EIT) can be partially ordered with respect to definiteness of the associated self-adjoint Neumann-to-Dirichlet operators. With this ordering, a pointwise larger conductivity leads to smaller current-voltage measurements, and smaller conductivities lead to larger measurements. We present a converse of this simple monotonicity relat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Medical Imaging
سال: 2012
ISSN: 0278-0062,1558-254X
DOI: 10.1109/tmi.2012.2204438