Shear-Wave Elastography: Basic Physics and Musculoskeletal Applications
نویسندگان
چکیده
منابع مشابه
Current status of musculoskeletal application of shear wave elastography
Ultrasonography (US) is a very powerful diagnostic modality for the musculoskeletal system due to the ability to perform real-time dynamic high-resolution examinations with the Doppler technique. In addition to acquiring morphologic data, we can now obtain biomechanical information by quantifying the elasticity of the musculoskeletal structures with US elastography. The earlier diagnosis of deg...
متن کاملMeasuring shear-wave speed with point shear-wave elastography and MR elastography: a phantom study
OBJECTIVES To compare shear-wave speed (SWS) measured by ultrasound-based point shear-wave elastography (pSWE) and MR elastography (MRE) on phantoms with a known shear modulus, and to assess method validity and variability. METHODS 5 homogeneous phantoms of different stiffnesses were made. Shear modulus was measured by a rheometer, and this value was used as the standard. 10 SWS measurements ...
متن کاملThree dimensional shear wave scattering MR elastography
Introduction: Magnetic resonance elastography (MRE) is a non invasive method that combines externally applied vibrations with the motion sensitivity of MRI to measure the shear elasticity soft tissues [1]. In MRE this is traditionally achieved by solving an inverse problem with MRE shear wave images as input data [2]. A complementary approach, which does not require the solution of an inverse p...
متن کاملShear-wave elastography for breast masses: local shear wave speed (m/sec) versus Young modulus (kPa)
PURPOSE To evaluate and compare the performance of shear-wave elastography (SWE) for breast masses using the local shear wave speed (m/sec) vs. Young modulus (kPa). METHODS A total of 130 breast lesions in 123 women who underwent SWE before ultrasound- guided core needle biopsy or surgical excision were included. With the region-of-interest placed over the stiffest areas of the lesion on SWE,...
متن کاملclinical application of shear wave elastography in breast masses
results of the 133 breast lesions, 32 were malignant and 101 were benign. in the differentiation of benign and malignant lesions, conventional us resulted in sensitivity of 100 %, specificity of 43.0 %, ppv of 57.1 %, npv of 36.7 %, and accuracy of 100 %. regarding swe, the sensitivity, specificity, ppv, npv, and accuracy values based on emax were 84.4 %, 89.1 %, 71.1 %, 94.7 %, and 88.0 %, res...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RadioGraphics
سال: 2017
ISSN: 0271-5333,1527-1323
DOI: 10.1148/rg.2017160116