Short and spaced twisted tapes to mitigate fouling in tubular membranes
نویسندگان
چکیده
منابع مشابه
Investigation of Thermo-hydraulic Performance of Circular Tube Fitted with Center-cleared Twisted Tape Using CFD Modeling (RESEARCH NOTE)
The article presents a practical technique for enhancing thermo-hydraulic performance of a circular tube. In this way, numerical method focusing on laminar tubular flow is used to compare the effectiveness of utilizing center-cleared twisted tapes instead of typical shape of short width tapes. Numerical analysis represented that using both center-cleared and typical shape of twisted tapes, Re e...
متن کاملTubular MFI Zeolite Membranes Made by In-Situ Crystallization
Polycrystalline MFI zeolite membranes were prepared on α-alumina tubular support by hydrothermal treatments at 413 K. The synthesized zeolite membranes were characterized by XRD, SEM and single gas permeation. The influence of hydrothermal treatment steps and the calcination time on the zeolite layer formation were investigated. MFI zeolite membrane prepared by four subsequent hydrothermal ...
متن کاملFrom chiral counterions to twisted membranes.
In membranes, the chirality of the amphiphile constituents is sometimes expressed at a supramolecular scale of nanometers or micrometers. We have recently reported that membranes of nonchiral dicationic n-2-n amphiphiles can also be chirally twisted upon interacting with chiral tartrate counterions. Here, we demonstrate that the mechanism of the chiral induction by counterions involves specific...
متن کاملElectro-Conductive Membranes for Permeation Enhancement and Fouling Mitigation: A Short Review
The research on electro-conductive membranes has expanded in recent years. These membranes have strong prospective as key components in next generation water treatment plants because they are engineered in order to enhance their performance in terms of separation, flux, fouling potential, and permselectivity. The present review summarizes recent developments in the preparation of electro-conduc...
متن کاملevaluation of twisted tapes performance in enhancement of condensing heat transfer and pressure drop
in this research, heat transfer enhancement and simultaneous effect of that on pressure drop inside condensers with twisted tape inserts are investigated. a refrigeration system is designed for attaining to maximum level of heat transfer with minimum pressure drop. the test condenser is a double pipe heat transformer with inner and outer diameter of 10.7mm and 12.7mm for internal pipe, respecti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Membrane Science
سال: 2020
ISSN: 0376-7388
DOI: 10.1016/j.memsci.2019.117426