Short-range vernier acuity: interactions of temporal frequency, temporal phase, and stimulus polarity
نویسندگان
چکیده
منابع مشابه
Short-range vernier acuity: interactions of temporal frequency, temporal phase, and stimulus polarity
We examined how vernier thresholds for flickering bars depend on the temporal frequency and relative temporal phase of the bars. The largest effect of relative phase (up to a fivefold increase in displacement thresholds) was seen at 2 Hz, and for most subjects, relative phase had little effect at 16 Hz and above. The effect of relative phase was essentially independent of contrast and trial dur...
متن کاملSpatio-temporal vernier acuity.
The study of space-time vernier (STV) provides information on the spatio-temporal structure of the visual system in the same way that the classical spatio-spatial vernier (SSV) provides information on its spatial structure. The transposition of a SSV task into a STV one yields the following experimental format: an object (in the present case a Gaussian Blob) drifts with a constant velocity, V, ...
متن کاملEffects of contrast and spatial frequency on vernier acuity.
We have examined vernier acuity using sinusoidal luminance gratings. Vernier thresholds were affected by both grating contrast and spatial frequency. With fixed (50%) contrast gratings, vernier thresholds reached minimum values of approximately 10 sec of arc at spatial frequencies between 6 and 16 c/deg. Vernier thresholds for all spatial frequencies are related to contrast by a power law with ...
متن کاملVernier acuity, crowding and amblyopia.
When a vernier target is flanked by a pair of optimally positioned flanks, offset discrimination is strongly degraded. Spatial interference with vernier acuity was studied in each eye of observers with unilateral amblyopia associated with strabismus, anisometropia or both, and were compared to the functions obtained in the normal periphery (Levi et al., 1985). The results showed that: (1) For b...
متن کاملResolution Acuity is better than Vernier Acuity
Our impressive sensitivity to vernier offsets as compared to resolution acuity has long inspired vision researchers to study the phenomena in great detail. In this study we use the test-pedestal framework to compare resolution and vernier acuity. In these experiments the test stimulus is the same for both tasks, only the pedestals differ. When thresholds are expressed in common units of test st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Vision Research
سال: 1999
ISSN: 0042-6989
DOI: 10.1016/s0042-6989(99)00054-1