An inquiry into the efficacy of 20 cm and 16 cm catheters placed in the right femoral vein of hemodialysis patients

Introduction: Today, temporary or permanent venous catheters are being increasingly used in patients with renal failure. It seems a necessity to be familiar with their clinical applications and complications as well as their efficacy. The aim of this study was to compare the efficacy of two catheters of 16 cm and 20 cm lengths. Methods: This research project was a descriptive, analytic study...

متن کامل

Detection of peritoneal pseudocyst following ventriculo-peritoneal shunt by radionuclide method [Persian]

A 14 years old boy who had a ventriculo-peritoneal shunt since the age of 5 months, was hospitalized due to headaches, nausea, vomiting and abdominal distension. In abdominal CT and sonographic evaluation, pancreatic pseudocyst or mesentric cyst were suspected. Evaluation of the shunt by radionuclide, however, was diagnostic and revealed a pseudocyst at the peritoneal end of the shunt. Th...

متن کامل

Peritoneal catheters and exit-site practices: toward optimum peritoneal access.

The peritoneal catheter is the CAPD patient's lifeline. Advances in catheter knowledge have made it possible to access the peritoneal cavity safely and maintain access over an extended period of time. Infection at the exit site remains a major problem, a solution for which is being extensively researched. The successful outcome of a catheter in an individual depends on meticulous care and adher...

متن کامل

an inquiry into the efficacy of 20 cm and 16 cm catheters placed in the right femoral vein of hemodialysis patients

introduction: today, temporary or permanent venous catheters are being increasingly used in patients with renal failure. it seems a necessity to be familiar with their clinical applications and complications as well as their efficacy. the aim of this study was to compare the efficacy of two catheters of 16 cm and 20 cm lengths. methods: this research project was a descriptive, analytic study co...

متن کامل

Why Do Some Mature Organizations Not Use Mature CM Tools?

This paper presents a case-study of a Configuration Management (CM) tool evaluation. The evaluation was performed in a company with a long tradition of using CM tools. Although several generations of CM tools have been developed internally, different reasons led to a decision not to use CM tools internally developed but to buy a tool available on the market. A detailed evaluation was performed ...