Significance of Face Velocity Fluctuation in Relation to Laboratory Fume Hood Performance

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Significance of face velocity fluctuation in relation to laboratory fume hood performance.

In order to recognize the problems associated with the transport mechanism of containment during the ventilation process of a laboratory fume hood, a transparent, full scale chemical fume hood is constructed for experimental studies. Distributions of mean velocity and velocity fluctuation in the sash plane are measured using a thermal anemometer. Flow patterns and tracer-gas concentration leaka...

متن کامل

morphology, geochemistry, mineralogy, and micromorphology of soils of hormozgan province in relation to parent materials

ویژگی های زمین شیمیایی، کانی شناسی، و میکرومورفولوژیکی خاک ها و سنگ مادر مربوطه در منطقه بین بخش های جنوبی زاگرس و خلیج فارس تا دریای عمان(استان هرمزگان، ایران) مورد بررسی قرار گرفت. هدف های این مطالعه شناسایی تغییرات در خصوصیات فیزیکی، شیمیایی، و ترکیب کانی شناسی خاک، مطالعه میکرومورفولوژی و تکامل خاک، و بررسی توزیع عنصر خاک بر اساس هوازدگی، پروسه های خاک و زمین شناسی جهت توصیف اثرات مواد مادر...

15 صفحه اول

ارزیابی عملکرد هودهای آزمایشگاهی براساس استاندارد  ASHRAE 110  در

Background and Aim: Laboratory fume-hoods are the first-level protection for the laboratory staff against hazardous chemical pollutants. Considering the large numbers of personnel, especially in petrochemical industry laboratories, this project was carried out in order to assess the performance of laboratory hoods based on tracer gas (SF6).Materials and Methods: In this project 22 hoods in the ...

متن کامل

the possibility of applying less tracer gas in ashrae-110-95 method of hood performance test

background and objective : a considerable amount of sulfur hexafluoride is applied to evaluate the performance of each laboratory hood according to ashrae–110-95 method. sf 6 is extremely hostile to environment and expensive. in present work, the possibility of conducting this method of hood performance test with less volume of sf 6 was investigated. material and methods : the performance of a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Industrial Health

سال: 2010

ISSN: 0019-8366,1880-8026

DOI: 10.2486/indhealth.48.43