Simplifying Electron Beam Channeling in STEM
نویسندگان
چکیده
منابع مشابه
Axial Channeling in Electron Diffraction
für Naturforschung in cooperation with the Max Planck Society for the Advancement of Science under a Creative Commons Attribution 4.0 International License. Dieses Werk wurde im Jahr 2013 vom Verlag Zeitschrift für Naturforschung in Zusammenarbeit mit der Max-Planck-Gesellschaft zur Förderung der Wissenschaften e.V. digitalisiert und unter folgender Lizenz veröffentlicht: Creative Commons Namen...
متن کاملDynamics of Electron Beam Channeling in Single Atomic Column and in Crystals
Manifestation of channeling effects in quantitative interpretation of atomic-resolution measurements made using scanning transmission electron microscope (STEM) has been observed in imaging and spectroscopic data [1-3]. Here, channeling refers to the path of the electron beam along atomic columns in a crystal. A feature common among STEM probe path in crystals of many different elemental compos...
متن کاملElectron channeling in TiO2 coated Cu layers
Electron transport in metal conductors with ~5-30 nm width is dominated by surface scattering. In situ transport measurements as a function of surface chemistry demonstrate that the primary parameter determining the surface scattering specularity is the localized surface density of states at the Fermi level N(Ef). In particular, the measured sheet resistance of epitaxial Cu(001) layers with thi...
متن کاملElectron emission channeling with position-sensitive detectors
Electron emission channeling allows direct lattice location studies of low doses of radioactive atoms implanted in single crystals. For that purpose the anisotropic emission yield of conversion electrons from the crystal surface is measured, most conveniently by use of position-sensitive detectors. We discuss characteristic features of this method, including quantitative data analysis procedure...
متن کاملPrecision Limits to STEM Imaging from Dynamical Scattering and Channeling of Sub-Angstrom Electron Probes
Precision smaller than the resolution is routinely achieved in electron microscopy, with 3-5 pm being the best reported for STEM [1], compared to 1-3 pm for TEM [2]. The signal to noise ratio (SNR) introduces the fundamental precision limit in STEM and TEM images. However, before the fundamental limit is reached, practical limits are usually encountered, such as image distortions caused by inst...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Microscopy and Microanalysis
سال: 2017
ISSN: 1431-9276,1435-8115
DOI: 10.1017/s1431927617002732