Simulatiomn of BHE fresh air air conditioning system based on TRNSYS-CFD Hybrid Simulation

نویسندگان

چکیده

In order to solve the problem of input fresh air overheating (cooling) in cold supply (heating) season severe regions, a soil source (BHE) combined with preheating conditioning system was studied net-zero energy building Shenyang. Firstly, hybrid TRNSYS-CFD simulation model based on TRNSYS and Fluent software established simulate operation indoor temperature distribution during typical day summer (winter) season. The allows simultaneous analysis operating characteristics real-time distribution. results show that accuracy is compared stand-alone by monitoring changes each room. room from average return air, while has stratification effect data more valuable for reference.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology

The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...

متن کامل

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

This paper presents results of a parametric study performed on an automotive air-conditioning (AAC) system of a passenger car. The goals are to assess the effects of varying the volumetric flow rate of supply air, number of occupants, vehicle speed, and the fractional ventilation air intake (XOA), on the dry-bulb temperature and specific humidity of the air inside the passenger’s cabin, and on ...

متن کامل

Numerical simulation and nasal air-conditioning

Heating and humidification of the respiratory air are the main functions of the nasal airways in addition to cleansing and olfaction. Optimal nasal air conditioning is mandatory for an ideal pulmonary gas exchange in order to avoid desiccation and adhesion of the alveolar capillary bed. The complex three-dimensional anatomical structure of the nose makes it impossible to perform detailed in viv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: E3S web of conferences

سال: 2022

ISSN: ['2555-0403', '2267-1242']

DOI: https://doi.org/10.1051/e3sconf/202235604013