Simulation and Hardware Implementation of Shunt Active Power Filter Based on Synchronous Reference Frame Theory
نویسندگان
چکیده
منابع مشابه
On design and implementation of three phase three level shunt active power filter for harmonic reduction using synchronous reference frame theory
Shunt active power filter is commonly used to eliminate current harmonics generated in the source side due to presence of non-linear loads. This scheme consists of three phase three level diode clamped multilevel inverter and a DC capacitor that act as a shunt active power filter to mitigate the supply current harmonics and inject the required reactive power to non-linear loads. In this paper, ...
متن کاملMitigation of Switching Harmonics in Shunt Active Power Filter Based on Variable Structure Control Approach
This paper presents a novel control approach used in shunt active power filter based on variable structure control combined with Random PWM technique (RVSC) that provides robust, fast, and more favorable performance for active power filter. This control strategy is compared with two other strategies to show the effectiveness of the introduced methods; pulse width modulated proportional-integral...
متن کاملDesign and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory
Active power filters are widely used for the reduction of harmonics in the power system caused by nonlinear loads. The Shunt Active Power Filter (SAPF) injects a suitable compensating current at a point of the line known as the point of common coupling (PCC) so that the harmonics present in the line are cancelled out and the sinusoidal nature of voltage and current waveforms are restored. A thr...
متن کاملStationary Frame Active Power Filter Control Based on Multiresolution Analysis
The paper presents an active power filter control method. The reference signal is generated in the stationary reference frame α-β using multiresolution analysis and the controllers used are P-resonant controllers, suitable for this particular application due to the fact that the steady-state error is zero for sinusoidal references with the frequency corresponding to the resonant frequency of th...
متن کاملMatlab Simulation of Single Phase Shunt Active Filter Based on PQ Theory
ABSTRACTThis paper presents the simulation of single phase shunt active filter based on PQ theory. Generally PQ theory is used for 3 phases 3 wires or 3 phases 4 wire system but here it is used for single phase system. This paper also concentrates hardly on reduction of THD of load current. Since the system has only single phase signal for both voltage and current, thus the dummy signal with 12...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: TELKOMNIKA (Telecommunication Computing Electronics and Control)
سال: 2018
ISSN: 2302-9293,1693-6930
DOI: 10.12928/telkomnika.v16i1.6524