Simultaneous delivery of two patent arterial duct coils via one venous sheath.
نویسندگان
چکیده
منابع مشابه
Simultaneous delivery of two patent arterial duct coils via one venous sheath.
A female child, 10 months of age, weighing 7.2 kg, was catheterised for closure of a patent arterial duct. Aortography was performed in the lateral projection and the minimum diameter of the arterial duct was assessed by comparing it to the size of the catheter. The duct size was estimated between 3 and 3.5 mm at the narrowest point, therefore, it was decided to deliver two 5 mm patent arterial...
متن کاملduct coils via one venous sheath . Simultaneous delivery of two patent arterial
Accepted for publication 28 May 1997 Abstract A female child, 10 months of age, weighing 7*2 kg, was catheterised for closure ofa patent arterial duct. Aortography was performed in the lateral projection and the minimum diameter of the arterial duct was assessed by comparing it to the size of the catheter. The duct size was estimated between 3 and 3 5 mm at the narrowest point, therefore, it wa...
متن کاملPatent arterial duct
Patent arterial duct (PAD) is a congenital heart abnormality defined as persistent patency in term infants older than three months. Isolated PAD is found in around 1 in 2000 full term infants. A higher prevalence is found in preterm infants, especially those with low birth weight. The female to male ratio is 2:1. Most patients are asymptomatic when the duct is small. With a moderate-to-large du...
متن کاملEvolution of strategies for management of the patent arterial duct.
Persistent patency of the arterial duct represents one of the most common lesions in the field of congenital cardiac disease. The strategies for management continue to evolve. In this review, we focus on management beyond the neonatal period. We review the temporal evolution of strategies for management, illustrate the currently available the techniques for permanent closure of the patent arter...
متن کاملAortic obstruction caused by device occlusion of patent arterial duct.
A 2 year old girl is reported in whom deployment of the Amplatzer ductal occluder caused significant aortic obstruction, requiring surgical removal of the device. This case emphasises the need for careful echocardiographic and angiographic assessment of the position of the Amplatzer ductal occluder before and after detaching the device from its delivery system, with particular emphasis on the p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Heart
سال: 1997
ISSN: 1355-6037
DOI: 10.1136/hrt.78.2.201