Simultaneous determination of miconazole and hydrocortisone or mometasone using reversed phase liquid chromatography

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of monosaccharides in cider by reversed-phase liquid chromatography

A reversed-phase high-performance liquid chromatographic (HPLC) method is described for the simultaneous determination of aldoses and uronic acids in cider, previously derivatized with p-aminobenzoic ethyl ester (ABEE). Narrow-bore C8 columns are recommended as this alternative provides good separation efficiency, along with greater economy and sensitivity. Detection limits for aldoses (glucose...

متن کامل

Simultaneous determination of retinol and retinyl esters in serum or plasma by reversed-phase high-performance liquid chromatography.

We propose a single-run liquid-chromatographic determination, with ultraviolet detection at 330 nm, for serum retinol and retinyl esters. The vitamin A derivatives are extracted according to the Bligh-Dyer procedure. With 200 microliter or serum, the lower detection limit is 50 microgram/liter for retinol and about 100 microgram/liter for retinyl esters. Within-run precision (CV) was 2.3% for r...

متن کامل

Simultaneous determination of diclofenac potassium and drotaverine hydrochloride in human plasma using reversed-phase high-performance liquid chromatography.

A simple high-performance liquid chromatographic method with ultraviolet detection is proposed for the estimation of diclofenac potassium and drotaverine hydrochloride in human plasma. Liquid-liquid extraction was carried out with a mixture of dichloromethane-isopropyl alcohol (80:20, v/v). Chromatographic separation of the analytes and internal standard was achieved on an analytical 250 × 4.6 ...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Hydrocortisone succinate and hydrocortisone simultaneously determined in plasma by reversed-phase liquid chromatography, and their pharmacokinetics in asthmatic children.

Hydrocortisone succinate and hydrocortisone are chromatographed with a mobile phase consisting of sodium acetate/acetonitrile (77/23, by vol), the effluent being monitored at 254 nm. p-Hydroxybenzoate-N-propyl is used as the internal standard. Detection limits are 0.5 mg/L for hydrocortisone succinate, 0.2 mg/L for hydrocortisone. For five different concentrations the respective mean analytical...