Simultaneous measurement of in-plane and out-of-plane displacement fields in scattering media using phase-contrast spectral optical coherence tomography

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous measurement of in-plane and out-of-plane displacement fields in scattering media using phase-contrast spectral optical coherence tomography.

The use of phase-contrast spectral optical coherence tomography to measure two orthogonal displacement components on a slice within a scattering medium is demonstrated. This is achieved by combining sequential oblique illumination of the object and recording two interferograms before plus two after the deformation. The proposed technique is illustrated with results from a sample undergoing simp...

متن کامل

Simultaneous measurement of in-plane and out-of-plane displacement elds in scattering media using phase-contrast spectral optical coherence tomography

The use of phase contrast spectral optical coherence tomography to measure two orthogonal displacement components on a slice within a scattering medium is demonstrated. This is achieved by combining sequential oblique illumination of the object and recording two interferograms before plus two after the deformation. The proposed technique is illustrated with results from a sample undergoing simp...

متن کامل

Electronic speckle pattern interferometry for simultaneous measurement of out-of-plane displacement and slope.

An optical configuration is presented for simultaneous measurement of out-of-plane displacement and slope change in electronic speckle pattern interferometry. Experimental results for a rectangular plate clamped along the edges and loaded at the center are presented.

متن کامل

Biometric measurement of the mouse eye using optical coherence tomography with focal plane advancement

PURPOSE To demonstrate that high-resolution biometry is possible in mouse eyes in vivo, using real-time OCT with focal plane advancement by a stepper motor. METHODS OCT images of eyes were taken from nine 29-day-old C57BL/6 mice(18 eyes) on two consecutive days. A custom-built real-time OCT instrument with a stepper motor was used to advance the focal plane from the corneal apex to the retina...

متن کامل

Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography.

From calibrated, weakly scattering tissue phantoms (2-6 mm-1), we extract the attenuation coefficient with an accuracy of 0.8 mm-1 from OCT data in the clinically relevant 'fixed focus' geometry. The data are analyzed using a single scattering model and a recently developed description of the confocal point spread function (PSF). We verify the validity of the single scattering model by a quanti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Letters

سال: 2009

ISSN: 0146-9592,1539-4794

DOI: 10.1364/ol.34.000806