Simultaneous transcutaneous carbon dioxide and transcutaneous oxygen monitoring in neonatal intensive care
نویسندگان
چکیده
منابع مشابه
Transcutaneous oxygen and carbon dioxide monitoring in intensive care.
Transcutaneous oxygen (TcPo2) and carbon dioxide (TcPco2) tensions were compared with arterial values in 23 children aged 4 months to 14 years, all requiring some form of respiratory support, but not in shock. Electrodes were placed on the upper chest and were heated to 45 degrees C. For TcPo2 and arterial oxygen (Pao2) a tight linear correlation over the range 6 to 14 kPa was found. Arterial c...
متن کاملTranscutaneous carbon dioxide monitoring: literature review.
Dental anxiety is very common, affecting 22% of the population. One way to increase access to dental care is by the use of BDZs in conscious sedation. These drugs are known to be safe when titrated. BDZs work by stimulating GABAA receptors within inhibitory pathways of the CNS. A consequence of this is a reduction in respiratory drive. Thus assessing saturation of peripheral oxygen (SpO2) is ma...
متن کاملMonitoring of end tidal carbon dioxide and transcutaneous carbon dioxide during neonatal transport.
OBJECTIVE To assess the accuracy of measurements of end tidal carbon dioxide (CO2) during neonatal transport compared with arterial and transcutaneous measurements. DESIGN Paired end tidal and transcutaneous CO2 recordings were taken frequently during road transport of 21 ventilated neonates. The first paired CO2 values were compared with an arterial blood gas. The differences between arteria...
متن کاملEnd-tidal carbon dioxide and transcutaneous carbon dioxide monitoring during neonatal transport
Abbreviations: CO2, Carbon dioxide; PaCO2, Arterial partial pressure of carbon dioxide; PtcCO2, Transcutaneous partial pressure of carbon dioxide; PetCO2, End-tidal partial pressure of carbon dioxide; NETS, Newborn Emergency Transport Service (Victoria); NICU, Neonatal Intensive Care Unit; PaO2/PAO2 ratio, alveolar-arterial ratio. ADC-FNN Online First, published on April 29, 2005 as 10.1136/adc...
متن کاملEvaluation of two combined oxygen and carbon dioxide transcutaneous sensors.
Two combined oxygen and carbon dioxide electrodes were assessed in neonates, infants, and children up to 16 years. They were convenient to use and the measurement error for PtcCO2 was acceptable. In both models, however, the PtcO2 electrode had a reduced performance compared with a single electrode.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Perinatal Medicine
سال: 1983
ISSN: 0300-5577,1619-3997
DOI: 10.1515/jpme.1983.11.1.51