Sliding Mode Control of DSTATCOM Using Seven Level Multilevel Inverter
In distribution system (DS), the majority of power consumption has been drawn in reactive loads. These loads are drawn in low power factor and therefore give rise to reactive power burden in the distribution system. So that DSTATCOM controller is used to compensate reactive power, correction of power factor and elimination of current harmonics. This paper presence the 7-Level Cascaded Hbridge I...
متن کاملDstatcom Based Five-level Cascade H-bridge Multilevel Inverter for Power Quality Improvement
Power electronic device, nonlinear and unbalanced loads have given rise to power quality problem in distribution systems. Due to factors like competitive generation patterns in a deregulated electric grid and an increasing level of sensitive end user devices, it has become necessary to ensure both reliable and power quality to the end customer. One way to betterment the power quality is using a...
متن کاملEffective Controller Design for the Cascaded H-bridge Multilevel DSTATCOM for Reactive Compensation in Distribution Utilities
The Static Synchronous Compensators (STATCOMs) have been recoginzed as the most effective solution for dynamic reactive power compensation, voltage stability enhancement and subsynchronous resonance damping purposes in the electric power systems. The STATCOMs in the distribution utilites (DSTATCOMs) are increasingly investigated for dynamic reactive power compensation and power quality improvem...
متن کاملSliding-Mode-based Improved Direct Active and Reactive Power Control of Doubly Fed Induction Generator under Unbalanced Grid Voltage Condition
This paper proposes an improved direct active and reactive power control (DPC) strategy for a grid-connected doubly fed induction generator (DFIG) based wind-turbine system under unbalanced grid voltage condition. The method produces required rotor voltage references based on the sliding mode control (SMC) approach in stationary reference frame, without the requirement of synchronous coordinate...
متن کاملComprehensive Analysis of LCL Filter Interfaced Cascaded H-Bridge Multilevel Inverter-Based DSTATCOM
Abstract: Three-phase two-level voltage source converters are used for distribution static compensator (DSTATCOM) applications and can be replaced by a multilevel inverter. In this paper, an LCL filter interfaced cascaded H-bridge multilevel inverter-based (CHBMLI) DSTATCOM is simulated and its performance is analyzed considering the system parameters. The analysis considers factors including t...