Somanetics INVOS 3100 Cerebral Oximeter

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy.

BACKGROUND Stroke is an important contributor to perioperative morbidity and mortality associated with carotid endarterectomy (CEA). This investigation was designed to compare the performance of the INVOS-3100 cerebral oximeter to neurologic function, as a means of detecting cerebral ischemia induced by carotid cross-clamping, in patients undergoing carotid endarterectomy with cervical plexus b...

متن کامل

Comparison of near-infrared spectroscopy and somatosensory evoked potentials for the detection of cerebral ischemia during carotid endarterectomy.

BACKGROUND AND PURPOSE We sought to assess the clinical value of regional cerebral saturation (rSO2) obtained by means of the cerebral oximeter INVOS 3100A (Somanetics) in comparison to monitoring of somatosensory evoked potentials (SEP) for the reliable detection of severe cerebral ischemia requiring shunt placement in the individual patient undergoing carotid surgery under general anesthesia....

متن کامل

Evaluation of pediatric near-infrared cerebral oximeter for cardiac disease.

BACKGROUND Cerebral hypoxia-ischemia remains a complication in children with congenital heart disease. Near-infrared spectroscopy can be utilized at the bedside to detect cerebral hypoxia-ischemia. This study aimed to calibrate and validate an advanced technology near-infrared cerebral oximeter for use in children with congenital heart disease. METHODS After institutional review board approva...

متن کامل

Cerebral oxygenation after birth – a comparison of INVOS® and FORE‐SIGHT™ near‐infrared spectroscopy oximeters

AIM To compare absolute values of regional cerebral tissue oxygenation (cStO2 ) during haemodynamic transition after birth and repeatability during steady state for two commercial near-infrared spectroscopy (NIRS) devices. METHODS In a prospective observational study, the INVOS 5100C and FORE-SIGHT were compared on 12 term newborns delivered by elective caesarean section. During the 10 min fo...

متن کامل

Cost analysis of patients undergoing cardiac surgery managed with or without cerebral oximetry (INVOS)

Methods A cost analysis of the INVOS group was done by comparing against 100 control patients who underwent surgery immediately prior to the INVOS audit. Hospital finance data was used to calculate costs. The areas for comparison were cost of: INVOS equipment; ICU and non-ICU postoperative LOS; stroke rehabilitation. Previous INVOS studies have focused on CABG only patients [2,3]. In order to c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Neurosurgery

سال: 1994

ISSN: 0148-396X,1524-4040

DOI: 10.1227/00006123-199410000-00043