Spatial resolution and peak-pressure-change measurement accuracy
نویسندگان
چکیده
منابع مشابه
Spatial resolution and peak-pressure-change measurement accuracy
Background It has been suggested that plantar pressures should be measured at ~6.2 mm to accurately characterize local maxima [1], and it has been shown that sensor widths of 10 mm can cause a 30% pressure underestimation at the metatarsal heads [2]. However, these results assume that pressure maxima, not maxima changes, are of primary interest. The purpose of this study was to examine how spat...
متن کاملInvestigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT
Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...
متن کاملAccuracy of non - invasive intracranial pressure measurement
Non-invasive measurement of intracranial pressure (ICP) reduces the complications and cost for both patient and health care systems. Improvement of non-invasive methods has led to development of systems for reproducing continuous, real-time non-invasive ICP signals. So far, non-invasive methods have been tailored for the patients with head trauma. We have used Schmidt’s auto-adaptive method to ...
متن کاملHigh Resolution Peak Measurement and Strain Mapping using Peak Pairs Analysis
Strain mapping is a numerical image-processing technique that measures the local shifts of an image with respect to the ideal positions in the bulk. Peak Pairs is a recently introduced real space algorithm for strain mapping. A new plug-in for DigitalMicrograph implementing Peak Pairs Analysis has been developed by HREM Research. It features high-resolution peak detection, image filtering, disp...
متن کاملDevelopment and characterization of a high-spatial-temporal-resolution foot-sole-pressure measurement system
Humans and biped robots generate unique pressure distributions under their feet while standing and walking. These foot pressure distributions are very vital information to analyze balance and walking in humans, and to analyze and control the gait cycles in robots. This research work involved development of a measurement system for measuring foot pressures using the Tekscan's F-Scan foot pressur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Foot and Ankle Research
سال: 2012
ISSN: 1757-1146
DOI: 10.1186/1757-1146-5-s1-o30