Specimen volume versus yield in the BACTEC blood culture system.

During a 24-month period, 5,625 blood culture specimens were collected at the Seattle Veterans Administration Medical Center in 20-ml volumes and divided into separate 10-ml aliquots. The two aliquots were processed as duplicate sets (set 1, set 2) by the BACTEC system (Johnston Laboratories, Inc., Towson, Md.). Specimens (5 ml) from each set were inoculated into aerobic (6B) and anaerobic (7C/...

متن کامل

Comparison of classical methods versus BACTEC blood culture system for culture of normally sterile body fluids

Background — Presence of microorganisms in sterile body sites leads to life-threatening infections. For early and accurate diagnosis of those infections, cultures of the sterile fluids have to be done. These cultures can not always detect the causative agents due to insufficent number or fastidious growing of the probable microorganisms in the material. Objectives — In this study, it was aimed ...

متن کامل

Effect of agitation and terminal subcultures on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia (M. P. Weinstein, S. Mirrett, and L. B. Reller, J. Clin. Microbiol. 26:962-964, 1988). To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive c...

متن کامل

Effect of altered headspace atmosphere on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

The one-bottle Oxoid Signal blood culture system altered to provide a more aerobic bottle headspace was reassessed in a comparative study versus the two-bottle BACTEC radiometric system in 5,426 blood cultures. The BACTEC system detected more microorganisms (P less than 0.02), particularly anaerobes (P less than 0.05) and fungi (P less than 0.05).

متن کامل

Utilization review of the use of BACTEC PLUS high-volume blood culture bottles.

The BACTEC PLUS 26 (NR26) (Becton Dickinson, Towson, Md.) high-volume blood culture bottle replaced the less expensive smaller-volume NR6A bottle in our hospital. An audit carried out several months after their introduction revealed that only 17.5% of the NR26 bottles received the required blood volume. Several audits and educational programs were required in order to achieve a compliance rate ...

متن کامل