Spectral Interferences in Atomic Absorption Spectrometry (II)

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

elimination of chemical and spectral interferences in measurement of trace elements in urine and blood by combined electrodeposition-electrothermal atomic absorption spectrometry

a combined electrodeposition-etaas technique has been applied to the analysis of pb, cd, co, ni, cr and mn in biological samples in order to overcome interferences and to minimize sample pretreatment. it requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. in an initial el...

متن کامل

Determination of Trace Copper(II) in Food Samples by Flame Atomic Absorption Spectrometry after Cloud Point Extraction

A new method for the determination of trace copper(II) in food samples by Cloud Point Extraction(CPE) combined with Flame Atomic Absorption Spectrometry(FAAS) is presented and evaluated. The method is based on the fact that hydrophobic complex of copper(II) with sodium diethyldithiocarbamate (DDTC) was formed at pH 6.0 and subsequently the hydrophobic complex was extracted into surfactant-r...

متن کامل

Interferences study for Selenium determination using of on Liquid Nitrogen Trap Hydride generation atomic absorption Spectrometry

A method has been developd determine selenium by hydride generation atomic absorption using nitrogen trapping technique. A series of experiments was performed to obtain the optimum condition. The results show that this method has the advantage of being sensitive, accurate, rapid and simple. Transition metal and other hydride forming elements interferences on the determination of selenium was st...

متن کامل

1 Atomic Absorption Spectrometry ( AAS )

Atomic Absorption Spectrometry (AAS) is a technique for measuring quantities of chemical elements present in environmental samples by measuring the absorbed radiation by the chemical element of interest. This is done by reading the spectra produced when the sample is excited by radiation. The atoms absorb ultraviolet or visible light and make transitions to higher energy levels. Atomic absorpti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the Spectroscopical Society of Japan

سال: 1978

ISSN: 1884-6785,0038-7002

DOI: 10.5111/bunkou.27.368