Spectroscopic imaging with prospective motion correction and retrospective phase correction
نویسندگان
چکیده
منابع مشابه
Spectroscopic imaging with prospective motion correction and retrospective phase correction.
Motion-induced artifacts are much harder to recognize in magnetic resonance spectroscopic imaging than in imaging experiments and can therefore lead to erroneous interpretation. A method for prospective motion correction based on an optical tracking system has recently been proposed and has already been successfully applied to single voxel spectroscopy. In this work, the utility of prospective ...
متن کاملPhase-Rotation for Spectroscopic Motion Correction
INTRODUCTION Spectral analysis depends heavily on enhanced peak resolution and narrow line widths. Increased line width due to motion can be a major source of error which contributes to a reduction in spectral quality. Thus, technical improvements obtained at short TE and high Bo fields are at risk in the presence of uncorrected motion artifacts. The increase in Bo field strength also demands a...
متن کاملCharacterisation of Motion-Induced Field Distortions in Spectroscopic Imaging With Prospective Motion Correction
Introduction The long scan duration makes spectroscopic imaging (SI) experiments particularly susceptible to motion-induced artifacts. Prospective motion correction based on an optical tracking system [1] has recently been proposed for 2D SI in the human brain [2]. Additionally, retrospective phase correction using the interleaved reference scan (IRS) method has been applied for the correction ...
متن کاملDiffusion imaging with prospective motion correction and reacquisition.
A major source of artifacts in diffusion-weighted imaging is subject motion. Slow bulk subject motion causes misalignment of data when more than one average or diffusion gradient direction is acquired. Fast bulk subject motion can cause signal dropout artifacts in diffusion-weighted images and results in erroneous derived maps, e.g., fractional anisotropy maps. To address both types of artifact...
متن کاملCombined Prospective Rigid-Body Motion Correction with Retrospective Non-Rigid Distortion Correction for EPI
Introduction: Prospective real-time motion correction, where the scan-plane orientation is dynamically updated to track with the subject's head during an MRI scan, is becoming increasingly popular (1-7). While these methods focus on compensating for bulk rigid-body motion, a secondary effect of head motion is non-rigid-body image distortion caused by changes in the effective shim within the bra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2011
ISSN: 0740-3194