Spring constant and sensitivity calibration of FluidFM micropipette cantilevers for force spectroscopy measurements

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An analytic model for accurate spring constant calibration of rectangular atomic force microscope cantilevers

Spring constant calibration of the atomic force microscope (AFM) cantilever is of fundamental importance for quantifying the force between the AFM cantilever tip and the sample. The calibration within the framework of thin plate theory undoubtedly has a higher accuracy and broader scope than that within the well-established beam theory. However, thin plate theory-based accurate analytic determi...

متن کامل

Spring constant calibration of atomic force microscope cantilevers of arbitrary shape.

The spring constant of an atomic force microscope cantilever is often needed for quantitative measurements. The calibration method of Sader et al. [Rev. Sci. Instrum. 70, 3967 (1999)] for a rectangular cantilever requires measurement of the resonant frequency and quality factor in fluid (typically air), and knowledge of its plan view dimensions. This intrinsically uses the hydrodynamic function...

متن کامل

Accurate Calibration and Uncertainty Estimation of the Normal Spring Constant of Various AFM Cantilevers

Measurement of force on a micro- or nano-Newton scale is important when exploring the mechanical properties of materials in the biophysics and nanomechanical fields. The atomic force microscope (AFM) is widely used in microforce measurement. The cantilever probe works as an AFM force sensor, and the spring constant of the cantilever is of great significance to the accuracy of the measurement re...

متن کامل

A method for determining the spring constant of cantilevers for atomic force microscopy

Cantilevers fabricated by means of micromachining techniques are usually used for atomic force microscopy. In this paper, the spring constant of an atomic force microscope (AFM) cantilever is determined by using a large-scale cantilever. Since the spring constant of the large-scale cantilever is calibrated accurately, the spring constant of the AFM cantilever is determined precisely by measurin...

متن کامل

Calibration of rectangular atomic force microscope cantilevers

A method to determine the spring constant of a rectangular atomic force microscope cantilever is proposed that relies solely on the measurement of the resonant frequency and quality factor of the cantilever in fluid ~typically air!, and knowledge of its plan view dimensions. This method gives very good accuracy and improves upon the previous formulation by Sader et al. @Rev. Sci. Instrum. 66, 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Scientific Reports

سال: 2019

ISSN: 2045-2322

DOI: 10.1038/s41598-019-46691-x