Square-Wave Cathodic Stripping Voltammetry of Ultratrace Manganese in the Presence of Ultrasound Irradiation.
نویسندگان
چکیده
منابع مشابه
Determination of abscisic acid by cathodic stripping square wave voltammetry.
In this paper a study is accomplished on behavior in a mercury electrode, of the phytohormone abscisic acid and of the conditions of accumulation in a HMDE. A mechanism is proposed of reduction based on its electrochemical behavior and proving the product of the reduction through mass spectrometry of bulks. A method is proposed for the determination of Abscisic acid (ABA) with a quantification ...
متن کاملDifferential pulse and square-wave cathodic stripping voltammetry of xanthine and xanthosine at a mercury electrode.
The surface activity of xanthine (Xan) and xanthosine (Xano) at a hanging mercury drop electrode (HMDE) was studied using out-of-phase ac and cyclic dc voltammetry. The results show that Xan and Xano were strongly adsorbed and chemically interacted with the charged mercury surface, which is the prerequisite step for applying the cathodic adsorptive stripping voltammetric determination of such b...
متن کاملDetermination of Aminophylline by Cathodic Stripping Voltammetry
Aminophylline is determined by cathodic stripping voltammetry (CSV) in BR buffer, pH 7.5 at a hanging mercury drop electrode. The detection limit was 3x10 M after 60 s accumulation at -0.60 V versus Ag/AgCl reference electrode. The linear range demonstrated up to 5x10 M using CSV. The interference caused by some purine derivatives, anions and some metal cations on the peak current was studied. ...
متن کاملDetermination of trace amounts of lead by adsorptive cathodic stripping voltammetry in the presence of xylenol orange
Lead forms the complexes with xylenol orange in the basic solution. An adsorptivedifferential pulse stripping method for the determination of lead is proposed. The procedureinvolves an adsorptive accumulation of lead on a hanging mercury drop electrode (HMDE) inthe presence of xylenol orange, followed by reduction of adsorbed lead by voltammetric scanusing differential pulse modulation. The opt...
متن کاملDetermination of chitosan by cathodic stripping voltammetry.
A sensitive method for the determination of chitosan (CTS) by cathodic stripping voltammetry is presented. The method exploits a pair of oxidation-reduction peaks of CTS at -0.62 V (vs. SCE) and -0.54 V (vs. SCE), and an enhancement of the peak current of CTS observed in a 0.05 mol l(-1) potassium hydrogenphthalate buffer solution (pH 2.5). The peak current is linear with the concentration of C...