Stability Analysis and Active Damping for <i>LLCL</i>-Filter-Based Grid-Connected Inverters
نویسندگان
چکیده
منابع مشابه
Stability Improvement of Grid-connected Converter with LCL Filter based on Capacitor Current Active Damping by Computational Delay Reduction
Nowadays, LCL filters utilization to suppress the grid-connected inverter switching harmonics is expanding and various methods such as capacitor current active damping scheme could be investigated to damp out these harmonics. However, the computational delays including control system, and PWM switching delays have significant effect on damping system stability. In most of LCL filter parameter d...
متن کاملH∞ Repetitive Control Based on Active Damping with Reduced Computation Delay for LCL-Type Grid-Connected Inverters
In the paper, the H∞ repetitive current control scheme based on active damping along with the design method is proposed for three-phase grid-connected inverters with inductor-capacitor-inductor (LCL) filters. The control scheme aims to reduce the harmonic distortion of the output currents and achieve better efficiency. The design method introduces capacitor-current-feedback active damping into ...
متن کاملCapacitor Current Feedback-Based Active Resonance Damping Strategies for Digitally-Controlled Inductive-Capacitive-Inductive-Filtered Grid-Connected Inverters
Inductive-capacitive-inductive (LCL)-type line filters are widely used in grid-connected voltage source inverters (VSIs), since they can provide substantially improved attenuation of switching harmonics in currents injected into the grid with lower cost, weight and power losses than their L-type counterparts. However, the inclusion of third order LCL network complicates the current control desi...
متن کاملPll for Single Phase Grid Connected Inverters
In grid connected applications the synchronization of output signals of the converters to be connected with grid parameters frequency and phase is of great importance. Different methods based on Fourier transforms, zero-crossing detection, Kalman filters, phase-locked loops (PLL) and others are used for this synchronization. This paper presents a new PLL for synchronization of the output curren...
متن کاملResonant Characteristics Analysis and Suppression Strategy of Multiple Parallel Grid-connected Inverters with LCL Filter
The multiple parallel inverters have more than one resonant frequency influenced by many factors, which tends to result in stability and power quality problems. This paper develops the multiple input multiple output model of the grid-connected inverters system using the closed-loop transfer function. The influence factors of resonant characteristics are analyzed with the developed model. The an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Journal of Industry Applications
سال: 2015
ISSN: 2187-1094,2187-1108
DOI: 10.1541/ieejjia.4.187