Stability Enhancement of DFIG Based Wind Turbine Under Three Phase Fault with STATCOM

نویسندگان

چکیده

The main aim of this paper is to improve the transient stability Doubly Fed Induction Generator (DFIG) based wind turbine using Static Synchronous Compensator (STATCOM). In paper, a multi-objective problem formulated minimize voltage deviations at point common coupling (PCC) and mitigate low frequency oscillations after clearing faults. Genetic algorithm STATCOM controller used enhance grid-connected farm composed variable-speed generator system (WTGS). performance proposed control scheme analyzed with three-phase fault. Simulations are carried out in MATLAB/Simulink environment.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power System Stability Enhancement under Three Phase Fault with FACTS Devices TCSC, STATCOM and UPFC

With the ever increasing complexities in power systems across the globe and the growing need to provide stable, secure, controlled, economic and high quality power especially in the deregulated power market. It is envisaged that FACTS controllers will play a vital role in power systems. This paper investigates the improvement of transient stability of a test system under three phase fault using...

متن کامل

Large Disturbance Stability Analysis of Wind Turbine Implemented with DFIG

As one of the most promising Distributed Generation (DG) sources, wind power technology has been widely developed in recent years. Doubly fed induction generator (DFIG) is currently employed as one of the most common topologies for wind turbine generators (WTGs). This generator operates as a synchronous/asynchronous hybrid generators. Therefore, it is necessary to power engineers find understan...

متن کامل

Large Disturbance Stability Analysis of Wind Turbine Implemented with DFIG

As one of the most promising Distributed Generation (DG) sources, wind power technology has been widely developed in recent years. Doubly fed induction generator (DFIG) is currently employed as one of the most common topologies for wind turbine generators (WTGs). This generator operates as a synchronous/asynchronous hybrid generators. Therefore, it is necessary to power engineers find understan...

متن کامل

Fault Ride through Capability Improvement of Wind Turbine Based DFIG Considering an Optimized Crowbar Along with STATCOM under Grid Fault Condition

Grid disturbances, especially grid faults, have very unfavorable effect on the performance of wind turbine based Doubly Fed Induction Generator (DFIG). In this study active and reactive powers control of DFIG with STATCOM has been carried out to improve Fault Ride Through (FRT) capability of a wind turbine. In order to excel improvement of the DFIG behavior under grid fault disturbances, an opt...

متن کامل

large disturbance stability analysis of wind turbine implemented with dfig

as one of the most promising distributed generation (dg) sources, wind power technology has been widely developed in recent years. doubly fed induction generator (dfig) is currently employed as one of the most common topologies for wind turbine generators (wtgs). this generator operates as a synchronous/asynchronous hybrid generators. therefore, it is necessary to power engineers find understan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Physics: Conference Series

سال: 2021

ISSN: ['1742-6588', '1742-6596']

DOI: https://doi.org/10.1088/1742-6596/1947/1/012061