STANMORE COMPARED WITH CHARNLEY TOTAL HIP REPLACEMENT
نویسندگان
چکیده
منابع مشابه
Stanmore compared with Charnley total hip replacement. A prospective study of 413 arthroplasties.
From 1982 to 1987, we randomised prospectively 413 patients requiring primary total hip replacements to receive either a Stanmore or Charnley prosthesis. They were reviewed by an independent observer in an attempt to correlate a number of factors including femoral head size with longevity. There were 213 Stanmore hips and 200 Charnley prostheses. At five to ten years (mean 6.5) 76 patients had ...
متن کاملThe Stanmore total hip replacement. A 22-year follow-up.
From a series of 135 patients (146 prostheses) who had had primary hip replacement in 1975 and 1976 we reported the outcome at ten years in 83 surviving patients in 1988 and that at 15 years in 44 surviving patients in 1994. Now, 22 years after the operation, we have reviewed the 21 patients who are still alive. Nineteen (20 hips) of these 21 patients (22 hips) with a mean age of 85.7 years sti...
متن کاملLong-term comparison of Charnley and Stanmore design total hip replacements.
We reviewed the records of the long-term outcome of 208 Charnley and 982 Stanmore total hip replacements (THR) performed by or under the supervision of one surgeon from 1973 to 1987. The Stanmore implant had a better survival rate before revision at 14 years (86% to 79%, p = 0.004), but the difference only became apparent at ten years. The later Stanmore implants did better than the early ones ...
متن کاملThe Stanmore total shoulder replacement.
Painful limitation of movement of the glenohumeral joint is most commonly the result of disorders of the pericapsular soft-tissues rather than the articular surfaces of the joint and treatment by operation is rarely required. There is nevertheless a small number of patients suffering from rheumatoid arthritis, avascular necrosis of the humerus or primary or post-traumatic arthritis of the gleno...
متن کاملPalamed G compared with Palacos R with gentamicin in Charnley total hip replacement. A randomised, radiostereometric study of 60 HIPS.
We performed a randomised, radiostereometric study comparing two different bone cements, one of which has been sparsely clinically documented. Randomisation of 60 total hip replacements (57 patients) into two groups of 30 was undertaken. All the patients were operated on using a cemented Charnley total hip replacement, the only difference between groups being the bone cement used to secure the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Journal of Bone and Joint Surgery. British volume
سال: 1996
ISSN: 0301-620X,2044-5377
DOI: 10.1302/0301-620x.78b2.0780178