Straightness Profile Measurement by Sequential Two-Point Method Utilizing a Laterally Shifting Reference plate
نویسندگان
چکیده
منابع مشابه
A novel method to enhance the sensitivity for two-degrees-of-freedom straightness measurement
A low cost and high precision system which can measure two-degrees-of-freedom straightness simultaneously is proposed based on a laser collimator. In the system, a miniature fiber coupled diode laser generates a collimating beam. The sensitivity of the straightness error measurement is magnified by a factor of 4 compared with the lateral movement of the retro-reflector itself after the multi-re...
متن کاملA straightness error measurement method matched new generation GPS
The axis of the non-diffracting beam produced by an axicon is very stable and can be adopted as the datum line to measure the spatial straightness error in continuous working distance, which may be short, medium or long. Though combining the non-diffracting beam datum-line with LVDT displace detector, a new straightness error measurement method is developed. Because the Non-diffracting beam dat...
متن کاملTwo-wave-plate compensator method for single-point retardation measurements.
The two-wave-plate compensator (TWC) technique is introduced for single-point retardation measurements. The TWC method uses a known wave plate together with a wave plate of unknown retardation and produces a linearly polarized output that allows a null of intensity to be detected. The TWC method is compared both theoretically and experimentally with the existing Brace-Köhler and Sénarmont metho...
متن کاملQuantitative measurement of reactive oxygen species in vivo by utilizing a novel method: chemiluminescence with an internal fluorescence as reference.
Reactive oxygen species (ROS) produced by photodynamic therapy (PDT) is recorded in vivo using a chemiluminescence (CL)-based gated optical system. A novel approach is developed to utilize the fluorescence (FL) of the CL probe as an internal fluorescence to calibrate the observed CL on pharmacokinetics of the probe in situ. The results show that during an in vivo PDT session, the intensity of C...
متن کاملVibration Analysis for Rectangular Plate Having a Circular Central Hole with Point Support by Rayleigh-Ritz Method
In this paper, the transverse vibrations of rectangular plate with circular central hole have been investigated and the natural frequencies of the mentioned plate with point supported by Rayleigh-Ritz Method have been obtained. In this research, the effect of the hole is taken into account by subtracting the energies of the hole domain from the total energies of the whole plate. To determine th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Japan Society for Precision Engineering
سال: 2014
ISSN: 0912-0289,1882-675X
DOI: 10.2493/jjspe.80.75