Disclaimer The contents of this report reflect the views of the author(s), who are responsible for the facts and the accuracy of information presented herein. This document i s disseminated under the sponsorship of the Center for Infrastructure Engineering Studies (CIES), University of Missouri-Rolla, in the interest of information exchange. CIES assumes no liability for the contents or use the...
متن کاملFrp Composites for Shear Strengthening of Rc Beams
ABSTRACT Fiber Reinforced Polymer (FRP) composite systems can be used for shear strengthening of reinforced concrete (RC) members. The present study investigated the shear performance and the modes of failure of simply supported RC T-beams externally strengthened in shear with FRP composites. Two different FRP-based strengthening systems were investigated, namely, externally bonded FRP sheets a...
متن کاملstrengthening of slender rc shear wall with frp sheets
concrete shear walls are the most prevalent structural systems resisting lateral loads due to earthquakes in high-rise buildings. very large in-plane stiffness of shear walls provides an excellent drift control in the structure. however, structural damages and early code shortcomings threaten the efficiency of existing structural walls against earthquake. recently, fiber reinforced polymer (frp...
متن کاملStructural behaviour of RC beams with external flexural and flexural–shear strengthening by FRP sheets
This paper presents experimental research on reinforced concrete (RC) beams with external flexural and flexural–shear strengthening by fibre reinforced polymer (FRP) sheets consisting of carbon FRP (CFRP) and glass FRP (GFRP). The work carried out has examined both the flexural and flexural–shear strengthening capacities of retrofitted RC beams and has indicated how different strengthening arra...
متن کاملMechanical Model to simulate the NSM FRP strips shear strength contribution to RC beams
A three dimensional mechanical model has been recently developed to simulate the Near Surface Mounted (NSM) Fibre Reinforced Polymer (FRP) strips shear strength contribution to Reinforced Concrete (RC) beams throughout the entire loading process, as function of the Critical Diagonal Crack (CDC) opening angle. It was developed by fulfilling equilibrium, kinematic compatibility and constitutive l...