Stress Correction Factor of Helical Springs
نویسندگان
چکیده
منابع مشابه
Stretching helical nano-springs at finite temperature
Using dynamic simulations and analytic methods, we study the elastic response of a helical filament subject to uniaxial tension over a wide range of bend and twist persistence length. A low-pitch helix at low temperatures exhibits a stretching instability and the force-extension curve consists of a sequence of spikes. At elevated temperature (i.e. small persistence lengths) the helix melts and ...
متن کاملStress Approximation Technique for Helical Compression Springs Subjected to Lateral Loading
Scott G. Keller University of Central Florida Orlando, Florida, USA Ali P. Gordon University of Central Florida Orlando, Florida, USA ABSTRACT Helical compression springs are commonly used devices capable of storing kinetic energy. Typical applications vary in simplicity, ranging from low stress amplitudes and in favorable environments, e.g. ball point pen spring at room temperature, to mill...
متن کاملStructure of cholesterol helical ribbons and self-assembling biological springs.
We report the results of x-ray-scattering studies of individual helical ribbons formed in multicomponent solutions of cholesterol solubilized by various surfactants. The solutions were chemically defined lipid concentrate (CDLC) and model bile. In these and many analogous multicomponent surfactant-cholesterol solutions, helical ribbons of two well defined pitch angles, namely 11 degrees and 54 ...
متن کاملFinite Element Solution of Dynamic Response of Helical Springs
Abstract A numerical solution is presented to describe wave propagations in axially impacted helical springs. The governing equations for such problem are two coupled hyperbolic, partial differential equations of second order. The axial and rotational strains and velocities are considered as principal dependent variables. Since the governing equations are non-linear, the solution of the system ...
متن کاملMechanics of patterned helical Si springs on Si substrate.
The elastic response, including the spring constant, of individual Si helical-shape submicron springs, was measured using a tip-cantilever assembly attached to a conventional atomic force microscope. The isolated, four-turn Si springs were fabricated using oblique angle deposition with substrate rotation, also known as the glancing angle deposition, on a templated Si substrate. The response of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of Japan Society of Spring Engineers
سال: 1971
ISSN: 0385-6917,1348-1479
DOI: 10.5346/trbane.1971.59