STRESS TRANSFER MECHANISM OF SOCKET BASE CONNECTION WITH PRECAST CONCRETE COLUMN
نویسندگان
چکیده
منابع مشابه
Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel
Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...
متن کاملDesign Considerations for the Connection of Precast Concrete Structures
The structural integrity of precast concrete buildings depends mainly on the connections between the precast structural components. Large precast concrete panels are used extensively in North America for low, medium, and highrise construction due to their ease and speed of assembly, and high quality control. This paper presents the results of twenty-two prototype specimens tested to investigate...
متن کاملPrecast Concrete Elements
Lattice-girder floor slabs and double-wall elements have been successfully used in building and industrial construction for decades. These precast elements of 50 – 70 mm thickness serve as permanent formwork for the subsequently added in-situ concrete creating a monolithic structure. The high prefabrication level allows the construction period to be significantly minimized. The main goal is the...
متن کاملFoam Concrete Precast Elements in Composite Concrete-GFRP Plate Girders
This paper is focused on using foam concrete as structural element in polymer-concrete composite plate girders. Trial mixes of foam concrete and different proportions of foam agent were considered to obtain the suitable mix that can be used as structural element in composite girders system. Details of the experimental investigations on foam concrete precast slabs and polymer-concrete composite ...
متن کاملSeismic Behavior of Prefabricated Column-Footing Connection
Results of an experimental investigation of the seismic performance of prefabricated column-footing connections are presented. Tests were conducted on six 1/4-scale prefabricated column specimens inserted into prefabricated footings in two Groups. Group-1 consisted of four specimens, which were tested under constant axial load and cyclic inelastic lateral displacements. The remaining two specim...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Structural and Construction Engineering (Transactions of AIJ)
سال: 1994
ISSN: 1340-4202,1881-8153
DOI: 10.3130/aijs.59.107